Results 11 to 20 of about 168,608 (266)

Influence of coil spacing on performance of resonant wireless power transmission system

open access: yesGong-kuang zidonghua, 2020
For coil spacing is a key indicator to measure wireless power transfer distance, influence of coil spacing on performance of resonant wireless power transmission system was studied.
QIAO Zhenpeng   +5 more
doaj   +1 more source

Power Quality Analysis of the Output Voltage of AC Voltage and Frequency Controllers Realized with Various Voltage Control Techniques

open access: yesApplied Sciences, 2021
Single-phase and three-phase AC-AC converters are employed in variable speed drive, induction heating systems, and grid voltage compensation. They are direct frequency and voltage controllers having no intermediate power conversion stage.
Naveed Ashraf   +3 more
doaj   +1 more source

DAB-based PET in MVDC traction and shipboard applications with distribution and redundant control

open access: yesThe Journal of Engineering, 2019
Medium-voltage DC (MVDC) grid has drawn more interest in the application of traction and large-scale ships, for its lower loss, higher reliability, higher controllability and simpler system architecture.
Wang You, Zheng Zedong, Li Yongdong
doaj   +1 more source

Current-limiting strategy based on PR controller and active power filter for droop controlled microgrid

open access: yesThe Journal of Engineering, 2019
In order to protect the power electronic equipment and make the output current amplitude of distributed generation (DG) maintain a stable value for different short-circuit faults, this paper proposed a current-limiting strategy based on proportional ...
Jie Gao, Xiaowei Wang, Fengfeng Yang
doaj   +1 more source

Predictive Nearest-Level Control Algorithm for Modular Multilevel Converters With Reduced Harmonic Distortion

open access: yesIEEE Access, 2021
Owing to the low number of submodules (SMs) in modular multilevel converters (MMCs), especially in medium-voltage applications, the output current and voltage generated by conventional nearest-level control (NLC) methods contain evident distortions ...
Minh Hoang Nguyen, Sangshin Kwak
doaj   +1 more source

Stabilising the output voltage of wireless power pickup through parallel tuned DC‐voltage controlled variable capacitor

open access: yesElectronics Letters, 2016
A new method to regulate the output voltage of the secondary side of an inductive power transfer (IPT) system through a DC‐voltage controlled variable capacitor (DCVC) is proposed.
J. Tian, A.P. Hu
doaj   +1 more source

EFEK LAJU PEMANASAN (HEATING RATE) TERHADAP DISTRIBUSI TEMPERATUR DAN KINERJA MODUL THERMOELECTRIC GENERATOR SP1848 SA

open access: yesRekayasa Mesin, 2023
Thermoelectric Generator (TEG) is an energy conversion technology that converts heat energy into electrical. There are several factors that affect the performance of TEG, one of which is the heat source.
Nugroho Tri Atmoko   +4 more
doaj   +1 more source

OPERATION OF DC-DC CHARGE PUMP CONVERTER MCP1253 IN BUCK MODE

open access: yesРоссийский технологический журнал, 2017
The algorithm of operation of MCP1253 charge pump converter in buck mode is studied for the first time by detailed measurements of ripples of output voltage and flying capacitor voltage.
V. K. Bityukov   +2 more
doaj   +1 more source

Overmodulation Strategy Using DC-Link Shunt Resistor Inverters to Maintain Output Voltage Linearity

open access: yesIEEE Access, 2021
To detect the three-phase current in the complex plane of a DC link shunt inverter, an algorithm for restoring the current is required. In this paper, a method of dividing the detection voltage and the compensation voltage to match the output voltage as ...
Soonho Kwon   +5 more
doaj   +1 more source

An AC voltage switching regulator with instantaneous output voltage control.

open access: yesIEEJ Transactions on Industry Applications, 1990
AbstractThis is the first attempt to control the instantaneous output of an ac/ac direct power converter. The ac chopper‐type regulator has the potential ability of quick response to the control command. However, detecting the mean or effective value of the ac output voltage, as is commonly done in the conventional closed‐loop ac regulators, greatly ...
Nomura, Hiroshi, Kawasaki, Naoya
openaire   +2 more sources

Home - About - Disclaimer - Privacy