Results 21 to 30 of about 764,053 (268)
Inverse time overcurrent protection can be applied to distribution networks with distributed power sources because of its superior protection characteristics, but its time limit coordination and value setting are complicated, which limits its large-scale
Yang Yu +4 more
doaj +1 more source
Protective coordination of main and backup overcurrent relays with different operating modes of active super-conducting current controller [PDF]
Active superconducting current controllers (ASCCs) are new generation of series compensators, which can also be categorised as fault current limiters because of their ability to decrease the fault current continuously.
Ahmad Ghafari +3 more
doaj +1 more source
Although traditional electromechanical circuit breakers have a proven track record as efficient and reliable circuit safety devices. Emerging power distribution technologies and architectures such as DC microgrids require advanced breaking performance ...
Muhammad Zulqair Nain, Tahir Mahmood
doaj +1 more source
Hybrid reed: Solid-state devices are a new generation of protective relays [PDF]
Research and development in the field of electromechanical protective relays has not been conducted for tens of years. Author’s approach allows viewing the problem of re-equipment of relay protection in a new way.
Gurevich Vladimir
doaj +1 more source
This paper proposes an impedance-accelerated inverse-time over-current protection optimization scheme based on the improved quantum genetic algorithm. First, the speed of remote backup protection is improved by increasing the optimization level of backup
Xia Zhang +4 more
doaj +1 more source
Distance protection and fault location of the PV power plants distribution lines
Unlike the synchronous generators, the short-circuit current provided by the photovoltaic (PV) sources is limited by the grid-connected inverters and closely related to the normal conditions, which impacts the protection of the power systems.
Elshiekh K. Mohammedsaeed +3 more
doaj +1 more source
Traditional methods to protect the electric-driven facilities from overload or short circuit usually use electronic breaker or fuse. However, the reaction time for these devices normally require more than 0.1 s that may be not sufficiently fast to ...
Hsiung-Cheng Lin +3 more
doaj +1 more source
Acute Neurological Events in Children With Hemoglobin SC Disease: A Multicenter Retrospective Study
ABSTRACT Introduction Neurological manifestations in children with hemoglobin SC (HbSC) disease remain insufficiently characterized, particularly regarding acute events. The aim of this study was to describe the spectrum and frequency of acute neurological events in a multicenter cohort of children with HbSC disease.
Célia Paulmin +11 more
wiley +1 more source
Optimal Coordination of Over-Current Relays in Microgrids Using Unsupervised Learning Techniques
Microgrids constitute complex systems that integrate distributed generation (DG) and feature different operational modes. The optimal coordination of directional over-current relays (DOCRs) in microgrids is a challenging task, especially if topology ...
Sergio D. Saldarriaga-Zuluaga +2 more
doaj +1 more source
ABSTRACT Background Therapeutic apheresis (TA) is an established treatment modality for hematologic, neurologic, and immunologic disorders, yet access remains severely limited in sub‐Saharan Africa. Donor apheresis, including platelet apheresis collection from healthy donors, represents an important complementary modality supporting blood product ...
Nosa Bazuaye +33 more
wiley +1 more source