Distance protection and fault location of the PV power plants distribution lines

open access: yesThe Journal of Engineering, 2019
Unlike the synchronous generators, the short-circuit current provided by the photovoltaic (PV) sources is limited by the grid-connected inverters and closely related to the normal conditions, which impacts the protection of the power systems.
Elshiekh K. Mohammedsaeed   +3 more
doaj   +1 more source

Development of fast electronic over-current protection circuit using current-adjustable sensing method

open access: yesAdvances in Mechanical Engineering, 2018
Traditional methods to protect the electric-driven facilities from overload or short circuit usually use electronic breaker or fuse. However, the reaction time for these devices normally require more than 0.1 s that may be not sufficiently fast to ...
Hsiung-Cheng Lin   +3 more
doaj   +1 more source

Therapeutic Apheresis in Nigeria: A Multi‐Center Summary of Abstracts From the Inaugural Nigerian Society for Apheresis Scientific Meeting

open access: yesTherapeutic Apheresis and Dialysis, EarlyView.
ABSTRACT Background Therapeutic apheresis (TA) is an established treatment modality for hematologic, neurologic, and immunologic disorders, yet access remains severely limited in sub‐Saharan Africa. Donor apheresis, including platelet apheresis collection from healthy donors, represents an important complementary modality supporting blood product ...
Nosa Bazuaye   +33 more
wiley   +1 more source

Optimal Coordination of Over-Current Relays in Microgrids Using Unsupervised Learning Techniques

open access: yesApplied Sciences, 2021
Microgrids constitute complex systems that integrate distributed generation (DG) and feature different operational modes. The optimal coordination of directional over-current relays (DOCRs) in microgrids is a challenging task, especially if topology ...
Sergio D. Saldarriaga-Zuluaga   +2 more
doaj   +1 more source

Establishing an Apheresis Medicine Program in a Resource‐Constrained Setting: A 5‐Year Experience From Lagos, Nigeria

open access: yesTherapeutic Apheresis and Dialysis, EarlyView.
ABSTRACT Background Establishing a comprehensive apheresis medicine program in a resource‐constrained setting presents significant structural, financial, and logistical challenges. Despite the growing clinical importance of apheresis services globally, published experience from sub‐Saharan Africa remains sparse.
Folasade Adelekan‐Popoola   +4 more
wiley   +1 more source

Verification of an IGBT Fusing Switch for Over-current Protection of the SNS HVCM [PDF]

open access: yes, 2010
An IGBT based over-current protection system has been developed to detect faults and limit the damage caused by faults in high voltage converter modulators.
Benwell, Andrew   +8 more
core   +1 more source

Analysis on Application of Impressed Current Cathodic Protection for Buried Pipelines under AC Interference

open access: yes, 2022
In order to study the effectiveness of pipeline cathodic protection system in preventing AC interference corrosion under AC interference, the testing device for stray current interference of buried steel pipelines was established, and the influence of ...
GUO Yong, DING Jifeng, GAO Zhixian, YIN An, ZHANG Bo, YANG Chaohui, LI Xiangyang
core   +1 more source

A Structure-Reconfigurable Soft-Switching DC-DC Converter for Wide-Range Applications

open access: yesEnergies, 2019
In this paper, a structure-reconfigurable resonant DC-DC (direct current − direct current) converter is presented. By controlling the state of the auxiliary switch, the converter could change the resonant structure to acquire a high efficiency and ...
Xianxu Huo   +5 more
doaj   +1 more source

Serum Myonectin Levels Are Positively Associated With Physical Function and Lower Frailty‐Related Limitation in Maintenance Hemodialysis Patients: A Cross‐Sectional Study

open access: yesTherapeutic Apheresis and Dialysis, EarlyView.
ABSTRACT Background Maintenance hemodialysis (MHD) patients frequently suffer from frailty, characterized by reduced physical function and poor prognosis. Myokines, such as myonectin, secreted by muscle, are emerging regulators of systemic health. This study investigated the relationship between serum myonectin, adipokines (adiponectin, omentin), and ...
Kenichi Kono   +7 more
wiley   +1 more source

Current–time characteristics of resistive superconducting fault current limiters

open access: yes, 2012
Superconducting fault current limiters (SFCLs) may play an important role in power-dense electrical systems. Therefore, it is important to understand the dynamic characteristics of SFCLs.
Burt, Graeme   +2 more
core   +1 more source