Results 41 to 50 of about 18,021,220 (286)
Application of symmetrical component method in protection system of bolter-miner
In view of problems of low reliability and accuracy of fault diagnosis of asynchronous motor in bolter-miner, symmetrical component method was purposed to apply in protection system of bolter-miner to realize asymmetry over-current fault diagnosis. Three-
JIAO Xiaofeng
doaj +1 more source
ABSTRACT Background Allogeneic hematopoietic stem cell transplantation (alloHSCT) is an essential therapy for several malignant and nonmalignant diseases, but relapse and graft loss remain the principal threats to its success. Routine monitoring of chimerism and minimal residual disease (MRD) enables early detection of imminent recurrence and guides ...
Carmen Junk +10 more
wiley +1 more source
Design of novel intrinsically safe power supply with 'ia' grade
According to working condition of mine-used power supply in coal mine underground, novel intrinsically safe power supply with 'ia' grade was designed. The power supply uses a fully enclosed AC-DC module to eliminate special flameproof enclosure, and has ...
YU Zhixue, FANG Xupeng, ZHAO Yang
doaj +1 more source
Over Current Protection for PFM Control DC-DC Converter
An over current protection method suitable for Fixed ON-time PFM (Pulse Frequency Modulation) Control DC-DC converters is proposed. It is based on inductor bottom current limiting, realized by monitoring the synchronous rectifier current and extending the OFF-phase of the main switch until it decreases to a predetermined limit, and can properly limit ...
YAMADA, Kouhei +2 more
openaire +1 more source
ABSTRACT Background Therapeutic apheresis (TA) is an established treatment modality for hematologic, neurologic, and immunologic disorders, yet access remains severely limited in sub‐Saharan Africa. Donor apheresis, including platelet apheresis collection from healthy donors, represents an important complementary modality supporting blood product ...
Nosa Bazuaye +33 more
wiley +1 more source
Optimization of grounding resistance in multitrain DC subway system based on MOEA/D‐DE
Currently, in multitrain DC subway system, abnormal increase of rail potential (RP) and stray current (SC) has seriously threatened the safe operation of the system.
Na Liu +7 more
doaj +1 more source
ABSTRACT Background Establishing a comprehensive apheresis medicine program in a resource‐constrained setting presents significant structural, financial, and logistical challenges. Despite the growing clinical importance of apheresis services globally, published experience from sub‐Saharan Africa remains sparse.
Folasade Adelekan‐Popoola +4 more
wiley +1 more source
Protecting AC microgrids (MGs) is a challenging task due to their dual operating modes—grid-connected and islanded—which cause sudden variations in fault currents. Traditional protection methods may no longer ensure network security.
León F. Serna-Montoya +3 more
doaj +1 more source
There is a difficulty in setting the coordination of over-current protection in the distribution network with distributed power sources and widely laying optical fiber for differential protection in the distribution network, the study on engineering ...
CHEN Yongkui, LI Hongmei, ZHU Jihong
doaj +1 more source
ABSTRACT Background Maintenance hemodialysis (MHD) patients frequently suffer from frailty, characterized by reduced physical function and poor prognosis. Myokines, such as myonectin, secreted by muscle, are emerging regulators of systemic health. This study investigated the relationship between serum myonectin, adipokines (adiponectin, omentin), and ...
Kenichi Kono +7 more
wiley +1 more source

