Results 11 to 20 of about 13,905,141 (291)

Aging of the over-voltage protection components

open access: yes2002 23rd International Conference on Microelectronics. Proceedings (Cat. No.02TH8595), 2003
The aim of this work was to examine the influence of the number of activations, i.e. over-voltage pulses, on the aging of over-voltage protection elements. Both nonlinear (gas-filled surge arresters (GFSA), varistors, over-voltage diodes), and linear (capacitors-constituents of filters) over-voltage protection elements were tested. The instruments used
Lončar, Boris   +2 more
openaire   +3 more sources

Aging of the over-voltage protection elements caused by over-voltages

open access: yesMicroelectronics Reliability, 2002
The aim of this work is examining the influence of the number of the activation––over-voltage pulses to the aging of over-voltage protection elements. Both non-linear (gas-filled surge arresters (GFSA), varistors, over-voltage diodes) and linear (capacitors––constituents of filters) over-voltage protection elements were tested. The instruments employed
Osmokrović, Predrag V.   +3 more
openaire   +6 more sources

The Innovative Method for Determining Characteristics of Over-Voltage Protection Elements

open access: yes2006 25th International Conference on Microelectronics, 2006
This paper presents an innovative method for efficient characterization of relevant characteristics of non-linear over-voltage protection elements in low-voltage applications. Standard measuring equipment is modified to enable an efficient and repeatable experimental procedure to investigate characteristics of over-voltage diodes and varistors: volt ...
Osmokrović, Predrag V.   +3 more
openaire   +4 more sources

Over voltage protection device for ROV

open access: yes, 2014
Supplying power to equipment always imposes a risk of damaging it. This risk is apparent in every application whether it be an industrial or a home appliance. One of these harmful occurrences is something like lightning which introduces a potentially harmful voltage in the system.
Kantzon, David, Lahti, Sebastian
core   +4 more sources

Over Voltage Protection Device Based on Multi-Strategy

open access: yesKey Engineering Materials, 2011
Strong electromagnetic interference occurs when the locomotive was running. Therefore, measurement errors resulted from interference exist when monitoring the rail potential only at single point. This will lead to misoperation of the protection device. An over voltage protection device based on multipoint and multi-strategy was designed.
Hai Tao Zhang, Gang Li
openaire   +2 more sources

Flexible protection architectures using distributed optical sensors [PDF]

open access: yes, 2012
In this paper we describe recent developments in flexible protection schemes that make use of passive fibre Bragg grating (FBG) based transducers for the distributed measurement of voltage and current.
Kawano, Fumio   +7 more
core   +4 more sources

High efficiency smart voltage regulating module for green mobile computing [PDF]

open access: yes, 2014
This thesis was submitted for the degree of Doctor of Philosophy and awarded by Brunel University.In this thesis a design for a smart high efficiency voltage regulating module capable of supplying the core of modern microprocessors incorporating dynamic ...
Tapou, Monaf Sabri
core   +5 more sources

All-optical differential current detection technique for unit protection applications [PDF]

open access: yes, 2013
In this paper we demonstrate a novel, all-optical differential current protection scheme. By monitoring the optical power reflected from two matched hybrid fiber Bragg grating current sensors and using a simple optoelectronic threshold detector, an ...
Philip Orr   +7 more
core   +4 more sources

Design of novel intrinsically safe power supply with 'ia' grade

open access: yesGong-kuang zidonghua, 2017
According to working condition of mine-used power supply in coal mine underground, novel intrinsically safe power supply with 'ia' grade was designed. The power supply uses a fully enclosed AC-DC module to eliminate special flameproof enclosure, and has ...
YU Zhixue, FANG Xupeng, ZHAO Yang
doaj   +1 more source

Over Voltage Protection Using Crowbar Devices for Low Voltage Loads [PDF]

open access: yes, 2015
All electronics and electrical instruments can be damaged mainly by voltage transient. This paper present s the development of over voltage protection circuits using crowbar devices such as SCR and TRIAC.
, Shahera S. Patel
core   +1 more source

Home - About - Disclaimer - Privacy