Results 21 to 30 of about 43,414 (164)

Review: Relay coordination in DGs with Electric Vehicle [PDF]

open access: yesE3S Web of Conferences
This research offers a comprehensive examination of the most effective approach to synchronize overcurrent relays within a protective system alongside protective relay.
ganji Srikant   +3 more
doaj   +1 more source

Analisis Sistem Proteksi pada Motor Circulating Water Pump PT. XYZ

open access: yesJurnal Mekanik Terapan
PT. XYZ melakukan penggantian motor circulating water pump tetapi alat proteksi yang digunakan belum disesuaikan dengan motor yang baru. Hal tersebut sangat berbahaya bagi peralatan, manusia maupun lingkungan sekitar.
Andi Ulfiana   +2 more
doaj   +1 more source

Koordinasi Sistem Proteksi Arus Lebih Pada Penyulang Distribusi 20 kV GI Pauh Limo

open access: yesJurnal Nasional Teknik Elektro, 2015
At 20 kV feeder outages typically caused by short circuit. If the adjustment over current relay (OCR) in the incoming or outgoing unfavorable, can cause a total blackout (black out). One of the efforts is by resetting the relay protection in distribution
Erliwati, Syafii, Muhammad Nurdin
doaj   +3 more sources

Optimal Coordination of Directional Overcurrent Relays in Microgrids Considering European and North American Curves

open access: yesEnergies
Protecting AC microgrids (MGs) is a challenging task due to their dual operating modes—grid-connected and islanded—which cause sudden variations in fault currents. Traditional protection methods may no longer ensure network security.
León F. Serna-Montoya   +3 more
doaj   +1 more source

Single‐Contact, Four‐Terminal Microelectromechanical Relay for Efficient Digital Logic

open access: yesAdvanced Electronic Materials, 2023
Nano and microelectromechanical relays can be used in lieu of transistors to build digital integrated circuits that can operate with zero leakage current at high operating temperatures and radiation levels. Four‐terminal (4‐T) relays facilitate efficient
James D. Reynolds   +6 more
doaj   +1 more source

Flutter Framework Implementation for Over Current Relay and Ground Fault Relay Setting Applications in 20 kV Distribution Systems

open access: yesJurnal Pendidikan Multimedia
In the distribution system, there are several faults such as blackouts due to errors in the coordination of the protection relay. To minimize excessive damage to the electrical system, components such as over current relays (OCR) are needed to overcome ...
Nike Sartika   +2 more
doaj   +1 more source

AC Microgrids Protection: A Digital Coordinated Adaptive Scheme

open access: yesApplied Sciences, 2021
A significant challenge for designing a coordinated and effective protection architecture of a microgrid (MG) is the aim of an efficient, reliable, and fast protection scheme for both the grid-connected and islanded modes of operation.
Noor Hussain   +6 more
doaj   +1 more source

Hybrid mixed-integer non-linear programming approach for directional over-current relay coordination

open access: yesThe Journal of Engineering, 2019
This article proposes the optimal coordination problem of protective relays within a hybrid optimisation framework which is presented based on integer coded genetic algorithm (ICGA) and non-linear programming (NLP).
Mohammad Sadegh Javadi   +4 more
doaj   +1 more source

High Performance Flexible Structure Three-Level DC-DC Converter: A Candidate DC Interface for Microgrids With Distributed Energy Resources

open access: yesIEEE Access, 2021
High-performance DC interfaces play a pivotal role in microgrids with distributed energy resources (DERs), which would significantly improve the utilization of DERs and the flexibility of the prosumers.
Yong Shi, Yiren Hu, Baoquan Liu
doaj   +1 more source

Analisis Koordinasi Over Current Relay Dan Ground Fault Relay Terhadap Keandalan Sistem

open access: yesJurnal Ilmiah Vastuwidya, 2020
This research had done base on case study in the feeder of substation 20 kV Jababeka. Existing data showed that condition is well with not too long differential, over all setting on the Overcurrent Relay (OCR) – Ground Fault Relay (GFR) in the field is well.
I Nengah Sunaya, I Gede Suputra Widharma
openaire   +2 more sources

Home - About - Disclaimer - Privacy