Results 11 to 20 of about 19,321 (267)
Overcurrent and Directional Overcurrent Protection for Microgrid
Microgrids will become common in future electrical distribution networks. Numerous operating modes that occur in microgrids make the development of protection schemes and settings challenging. This paper aims to develop a simple protection scheme for the Microgrid IEC Benchmark without any expensive equipment such as communication apparatus.
Zahira Shiva Salsabila +2 more
openaire +1 more source
Electricity is delivered to end users through generation, transmission, and distribution phases. The most important issues during energy journey is to provide selective, rapid, and safe protection to ensure energy continuity.
Uğur Arifoğlu +2 more
doaj +1 more source
Study on the IGBT Overcurrent Failure of VSC-HVDC Converter Valve
IGBT overcurrent failure, which is one of the important factors harming VSC-HVDC safe operation, can easily lead to module explosion, water cooling system leakage and even the converter valve shutdown.
Jingbo FENG +4 more
doaj +1 more source
The optimum setting of directional overcurrent relays (DOCRs) is required to avoid miscoordination and avail fast response. To fulfill these requirements, it is required to prefer optimization techniques and modifications in objective functions (OF ...
Shanker D. Godwal +4 more
doaj +1 more source
The increasing penetration of renewable energy sources in distribution networks has caused great challenges to the reliable operation of the conventional overcurrent protection schemes.
Lijing Sun +6 more
doaj +1 more source
Overcurrent abuse has been performed on commercial 48 Ah primary prismatic zinc (Zn)–Air battery cells with full air supply as well as with shut-off air supply.
Fredrik Larsson +4 more
doaj +1 more source
Improvement of overcurrent protection for control rod drive mechanism power system
Control rod drive mechanism (CRDM) in nuclear reactors powered by two motor generator units running in parallel, an excitation fault in one of the generators will cause the terminal current to rise in another generator, which will cause the overcurrent ...
Lingjin Zhu +7 more
doaj +1 more source
Analysis and hardware testing of cell capacitor discharge currents during DC faults in half-bridge modular multilevel converters [PDF]
This paper focuses on the behaviour of the cell capacitor discharge currents during DC faults in half-bridge modular multilevel converters. Active switches, not designed for fault conditions, are tripped to minimize discharge currents effect on the ...
Aboushady, A.A., Ahmed, K.H., Jovcic, D.
core +2 more sources
Fireproof and energy saving mobile phone charger
Both forgetting to unplug mobile phone chargers after using and generating large surge current when the charger is plugged into power, will accelerate the aging of high-voltage electronic components. It is also prone to failure and fire. In addition, the
Yin Jingwen, Lin Jinghu, Jin Yonggao
doaj +1 more source
Thermal analysis of lithium ion battery-equipped smartphone explosions [PDF]
Thermal management of mobile electronics has been carried out because performance of the application processor has increased and power dissipation in miniaturized devices is proportional to its functionalities.
Chen +23 more