Results 101 to 110 of about 3,412 (219)
Automatic detection device for mining intrinsic safety power supply based on PWM
Aiming at the problems of cumbersome factory inspection steps, low inspection efficiency, and poor consistency of protection parameter measurement results for intrinsically safe power supplies used in mining, a high-precision fully automatic factory ...
Dedong ZOU
doaj +1 more source
The inevitable diminutions of fossil fuel, declined energy efficiency, and sustainability considerations have sparked concerns about centralized generating facilities in traditional grids.
Abdelfattah A. Eladl +4 more
doaj +1 more source
Adaptive Overcurrent Protection in Industrial Distribution Systems with Distributed Generation
Protection of industrial distribution systems is paramount for the economic stability of any nation. Failures in industrial or commercial distribution systems involves great deal of monetary losses.
Abraham, Linus
core
Active distribution grid with tie switches has a complex grid structure and undergo frequent changes in operation mode, which greatly affects the correct operation of traditional current protection that relies on static grid topology and fixed operation ...
Nuo CHENG +5 more
doaj +1 more source
A review of overcurrent protection methods for solar photovoltaic DC circuits [PDF]
This paper investigates the current methodology for overcurrent protection in grid-connected solar photovoltaic (PV) systems. Overcurrent testing procedures for PV modules are examined.
C. Reading (7210397) +2 more
core
The recent development of protection coordination schemes based on inverse of AC microgrid: A review
Integration of distributed generation systems and diversity of microgrid operations led to a change in the structure of the power system. Due to this conversion, new challenges have arisen when employing traditional overcurrent protection schemes.
Mustafa, Haytham +7 more
core +1 more source
Investigation of Overcurrent Relay Tripping Time Protection Using PSCAD Software
This paper studied the modelling of 132/33/11kV overcurrent protection by using PSCAD software. The objective of this project is to compare between IEC 60255 Standard and IEEE C37.112 Standard overcurrent relay response time in the event of fault current.
Mohd Hendra Hairi +3 more
core +1 more source
Overcurrent and protection of current cutoff
Fen Bilimleri Enstitüsü, Elektrik-Elektronik Mühendisliği Ana Bilim DalıÖzetYüksek Lisans TeziAŞIRI AKIM VE AKIM KESİNTİLERİ KORUMASIArş. Gör. Didem AltunYüksek Lisans TeziElektrik Elektronik MühendisliğiAnabilim DalıAralık 2006Danışman : Doç. Dr. Rafael
Altun, Didem
core
Adaptive overcurrent protection considering fault current limiters effect. [PDF]
Mahmoud RA, Ghaly KG, Hasan SA.
europepmc +1 more source
Design and development of an overcurrent protection relay
Elektrik güç sistemleri, hızlı bir şekilde ele alınmazsa, pahalı ekipmana zarar verebilecek ve en kötü durumda birine bile zarar verebilecek farklı arıza türlerine karşı sıklıkla savunmasızdır. Güç sistemleri için sorun yaratabilecek bazı arıza türleri örn. aşırı gerilim, aşırı akım ve düşük gerilim.
openaire +1 more source

