Results 71 to 80 of about 340 (134)
Optimization Techniques for Directional Overcurrent Relay Coordination: A Comprehensive Review
This paper provides a comprehensive review of optimization techniques for coordinating directional overcurrent relays in power systems. It covers a wide range of techniques, including conventional and deterministic methods, metaheuristic algorithms, and ...
Tareq Foqha +3 more
doaj +1 more source
Advent of distributed generation and progression towards an intelligent grid infrastructure within the domain of contemporary electrical power systems have created dynamic load profiles.
Samira Sadeghi +3 more
doaj +1 more source
The calculation of the output current of distribution generation (DG) units interfaced with an inverter during the fault is a major issue for isolated and grid-connected distributed networks. The droop control inverter interfaced DG has controlled output
Mahmoud Aref +5 more
doaj +1 more source
Design and development of an overcurrent protection relay
Elektrik güç sistemleri, hızlı bir şekilde ele alınmazsa, pahalı ekipmana zarar verebilecek ve en kötü durumda birine bile zarar verebilecek farklı arıza türlerine karşı sıklıkla savunmasızdır. Güç sistemleri için sorun yaratabilecek bazı arıza türleri örn. aşırı gerilim, aşırı akım ve düşük gerilim.
openaire +1 more source
The aim of the relay coordination is that protection systems detect and isolate the faulted part as fast and selective as possible. On the other hand, in order to reduce the fault clearing time, distance protection relays are usually equipped with pilot ...
Y. Damchi, J. Sadeh, H. Rajabi Mashhadi
doaj
The Effect of Current Harmonic on Overcurrent Relay
Muhammad Hafiz Mohd Rohaizad +2 more
openaire +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Microprocessor-Based Overcurrent Relays
IEEE Transactions on Industrial Electronics, 1986Inverse overcurrent is normally associated with the overcurrent relay types, the operation time is inversely proportional (in certain degrees) with their overcurrent ratio.
Mudhafar A. Al-Nema +2 more
exaly +2 more sources
IEEE Transactions on Power Delivery, 2011
In this paper, a new objective function (OF) within the genetic algorithm (GA) approach is presented to solve the optimization problem of coordination of overcurrent and distance relays. The existing objective function of overcurrent (O/C) relays coordination is improved and extended to include the coordination of O/C and distance relays.
Hossein Askarian Abyaneh +2 more
exaly +2 more sources
In this paper, a new objective function (OF) within the genetic algorithm (GA) approach is presented to solve the optimization problem of coordination of overcurrent and distance relays. The existing objective function of overcurrent (O/C) relays coordination is improved and extended to include the coordination of O/C and distance relays.
Hossein Askarian Abyaneh +2 more
exaly +2 more sources
The Universal Overcurrent Relay
IEEE Industry Applications Magazine, 1996A comprehensive list of nondirectional overcurrent relays would include thermal overload, inverse-time, definite time, and instantaneous relays. The list could be further classified by operating quantities including individual phase, residual, and negative-sequence current.
E. O. Schweitzer, S. E. Zocholl
openaire +1 more source
Electric Power Systems Research, 1996
Abstract This paper presents the design and construction of overcurrent and directional overcurrent relays with ground fault protection for the protection of three-phase subtransmission and distribution systems, using a 16-bit microprocessor, the Intel 8096BH. The relay obtains the system currents at the rate of 12 samples per cycle and estimates the
Zhijun, G., Elangovan, S., Liew, A.C.
openaire +1 more source
Abstract This paper presents the design and construction of overcurrent and directional overcurrent relays with ground fault protection for the protection of three-phase subtransmission and distribution systems, using a 16-bit microprocessor, the Intel 8096BH. The relay obtains the system currents at the rate of 12 samples per cycle and estimates the
Zhijun, G., Elangovan, S., Liew, A.C.
openaire +1 more source

