Results 1 to 10 of about 17,891 (304)
Atmospheric Sensors and Energy Harvesters on Overhead Power Lines. [PDF]
We demonstrate the feasibility of using novel, small energy harvesters to power atmospheric sensors and radios simply attached to a single conductor of existing overhead power distribution lines. We demonstrate the ability to harvest the required power for operating multiple atmospheric and power-system sensors, together with short-range radios that ...
White RM, Nguyen DS, Wu Z, Wright PK.
europepmc +5 more sources
Proximity to overhead power lines and childhood leukaemia: an international pooled analysis. [PDF]
Although studies have consistently found an association between childhood leukaemia risk and magnetic fields, the associations between childhood leukaemia and distance to overhead power lines have been inconsistent. We pooled data from multiple studies to assess the association with distance and evaluate whether it is due to magnetic fields or other ...
Amoon AT +25 more
europepmc +15 more sources
Influence of Ambient Temperature on the Reliability of Overhead LV Power Lines with Bare Conductors
The article presents a study on the influence of weather factors (ambient temperature) on the operational reliability of overhead low-voltage power lines with bare conductors.
Kornelia Banasik
doaj +3 more sources
Method for Calculating of Lightning Impact Level on Overhead Transmission Line
This paper proposes a simple method for calculating the lightning impact level on overhead transmission power lines, taking into account its entire length. The method uses lightning historical data and the geographic coordinates of power line towers.
Anton Vladimirovich Burtsev +1 more
doaj +1 more source
Introduction. The problem of estimating power losses in grounding wires with built-in fiber optic cable for overhead power lines of voltage class 330-750 kV is relevant, while it is obvious that the amount of losses depends on the chosen brand of wire ...
A. V. Krasnozhon +4 more
doaj +1 more source
Characteristics of lightning‐induced voltages based on experimental data
This paper presents an analysis of 64 lightning‐induced voltage waveforms recorded in an experimental system implemented in the campus of the University of São Paulo, Brazil.
Michele N. N. Santos, Alexandre Piantini
doaj +1 more source
The electrical grid of regional power systems primarily uses double-circuit 220 kV overhead power lines to function. This paper provides information on the problem of ice formation on overhead ground wires of 220 kV power lines, including a brief ...
Krotkov E.A. +2 more
doaj +1 more source
Fault location on overhead power lines achieved with the highest possible accuracy can reduce the time to locate faults. This contributes to ensuring the stability of power systems, as well as the reliability of power supply to consumers.
Aleksandr Kulikov +3 more
doaj +1 more source
Breakage Mechanism Study of Overhead Ground Wire Under Lighting Stroke Based On Finite Element Analysis [PDF]
Breakage of overhead transmission lines and distribution lines will lead to severe power outage problems, and clarifying the breakage mechanism of the overhead lines is of great importance and value for the reliability and stability of the power system ...
Xia Yunfeng +4 more
doaj +1 more source
To supply stable and high-quality power according to the advancement of industrial growth, electric power companies have performed maintenance of power facilities using various methods.
Hyeseon Lee +4 more
doaj +1 more source