Results 51 to 60 of about 124,242 (306)
An equivalent circuit for the evaluation of cross-country fault currents in medium voltage (MV) distribution networks [PDF]
A Cross-Country Fault (CCF) is the simultaneous occurrence of a couple of Line-to-Ground Faults (LGFs), affecting different phases of same feeder or of two distinct ones, at different fault locations.
Gatta, Fabio Massimo +3 more
core +1 more source
Multi‐Functional ZnO–Te Heterojunction Devices Enabling Compact Frequency Quadrupler
Wafer‐scale ZnO–Te heterojunction devices featuring tunable double negative differential transconductance (D‐NDT) are demonstrated at ≤ 200°C. Leveraging this unique characteristic, a single‐stage frequency quadrupler is realized, achieving a 64%–75% reduction in device count.
Jae Hyeon Jun +8 more
wiley +1 more source
The Influence of Climatic Conditions on the Dynamic Ampacity of Overhead Power Lines
The constantly growing demand for electricity demands both on the installed power of energy sources and on the transmission capabilities of electrical networks.
Beňa Ľubomír +2 more
doaj +1 more source
Ground Transient Resistance of Underground Cables [PDF]
During transients involving multiconductor lines, the importance of the ground finite conductivity is well known and various techniques and expressions have been presented in literature for the inclusion of its contribution into the per unit length ...
Araneo, Rodolfo, Celozzi, Salvatore
core +1 more source
The perspective presents an integrated view of neuromorphic technologies, from device physics to real‐time applicability, while highlighting the necessity of full‐stack co‐optimization. By outlining practical hardware‐level strategies to exploit device behavior and mitigate non‐idealities, it shows pathways for building efficient, scalable, and ...
Kapil Bhardwaj +8 more
wiley +1 more source
Power frequency interference and suppression in measurement of power transmission tower grounding resistance [PDF]
“If you want peace, work for justice.” – Pope Paul VI This paper explores how the children’s right to be heard is implemented in the criminal proceedings in Romania and Norway.
Wenjun, Zhou +7 more
core +3 more sources
In the context of the construction of novel power systems, the thermal stability limit capacity of overhead distribution lines, especially the transmission capacity of interconnected lines in N-1 mode, has become a bottleneck that restricts the flexible ...
ZHANG Shusen +5 more
doaj +1 more source
As the key equipment in power system, the running state of overhead transmission lines is affected by various complex and random factors, and the maintenance workload of the line is too heavy to overhaul regularly.
Jiaxin Liu +6 more
doaj +1 more source
Lighting performance study on existing 275KV overhead line in TNB system [PDF]
Lightning is the primary cause of tripping for most overhead power transmission lines. Few methods have heen discovered to estimate the lightning performance of a transmission line.
Thamodharan, Muralitharan
core
Transducers convert physical signals into electrical and optical representations, yet each mechanism is bounded by intrinsic trade‐offs across bandwidth, sensitivity, speed, and energy. This review maps transduction mechanisms across physical scale and frequency, showing how heterogeneous integration and multiphysics co‐design transform isolated ...
Aolei Xu +8 more
wiley +1 more source

