Results 1 to 10 of about 14,185 (237)
Delta-Bar-Delta and directed random search algorithms to study capacitor banks switching overvoltages [PDF]
This paper introduces an approach to analyse transient overvoltages during capacitor banks switching based on artificial neural networks (ANN). Three learning algorithms, delta-bar-delta (DBD), extended delta-bar-delta (EDBD) and directed random
Sadeghkhani Iman +2 more
doaj +3 more sources
Characterization of lightning-induced overvoltages in wind farms. [PDF]
Wind farms are exposed to various weather hazards, including lightning strikes, which can pose significant risks. However, the impact of different wind farm topologies on the magnitude of lightning-induced overvoltages has not been extensively studied ...
Tamer Eliyan +3 more
doaj +2 more sources
Assessment of the hazard risks on HVDC transmission networks due to lightning strikes and faults. [PDF]
HVDC systems with high voltage and direct current are suitable for reducing electricity losses, during transmission over long distances. However, HVDC lines have the highest probability of failure within a system and can be damaged by different faults or
Abdelrahman Said +2 more
doaj +2 more sources
Insulation stresses of power equipment exposed to non-standard overvoltage waveforms [PDF]
During its operation, electrical equipment is constantly exposed to overvoltages of various waveforms, such as lightning discharges, switching operations, faults, etc.
Jasika Ranko +2 more
doaj +1 more source
The numerical method of inverse Laplace transform for calculation of overvoltages in power transformers and test results [PDF]
A methodology for calculation of overvoltages in transformer windings, based on a numerical method of inverse Laplace transform, is presented.
Mikulović Jovan Č. +1 more
doaj +1 more source
Overvoltage in medium voltage networks [PDF]
The causes of overvoltages in medium voltage networks can be not only atmospheric discharges and switching processes, but also certain operational states. The purpose of the study is to analyze overvoltages in medium voltage networks with atmospheric
E. A. Krotenko
doaj +1 more source
Since the Electromagnetic Transient (EMT) process of the high-voltage submarine cable has a great influence on the safe and stable operation of the transmission system, it is necessary to analyze its EMT process under actual engineering.
Han Li +3 more
doaj +1 more source
Overvoltages transferred from a network of 220 kV to 15.65 kV level of the step-up transformer in HPP 'Bajina Bašta' [PDF]
The paper presents the results of research in lightning surge waves and switching overvoltages transferred from a network of 220 kV to the 15.65 kV level of the step-up transformer in HPP 'Bajina Bašta'. Analysis of survey results lead to conclusion that
Vukelja Petar, Mrvić Jovan
doaj +1 more source
In the latest research, it has been proven that from the point of view of losses in a cable distribution line, the most advantageous operation is to work with two or one phase of metallic cable screen ungrounded.
Aleksandra Schött-Szymczak +1 more
doaj +1 more source
Vacuum circuit breakers are increasingly used as switching apparatus in electric power systems. The vacuum circuit breakers (VCBs) have very good operating properties. VCBs are characterized by specific physical phenomena that affect overvoltage exposure
Marek Florkowski +3 more
doaj +1 more source