Results 51 to 60 of about 1,743,977 (90)

Oxygen saturation during reaming and intramedullary nailing of the femur

open access: yes, 1992
Oxygen saturation was monitored during the reaming and intramedullary nailing of 15 femoral fractures (three impending) to assess the relationship between intramedullary reaming and nailing and the production of hypoxemia.
Blitzer, Charles M.   +3 more
core   +1 more source

Femoral venous oxygen saturation is no surrogate for central venous oxygen saturation*

open access: yesCritical Care Medicine, 2012
The purpose of our study was to determine if central venous oxygen saturation and femoral venous oxygen saturation can be used interchangeably during surgery and in critically ill patients.Prospective observational controlled study.Nonacademic university-affiliated teaching hospital in The Netherlands.One hundred cardiac outpatients, 30 high-risk ...
van Beest, Paul A.   +9 more
openaire   +4 more sources
Some of the next articles are maybe not open access.

Related searches:

Oxygen saturation

2021
Abstract This chapter describes how desaturation during a cardiopulmonary exercise test (CPET) is uncommon. A fall of more than 4% from resting values is considered abnormal. Oxygen desaturation is usually caused by lung or pulmonary vascular disease, reflecting ventilation–perfusion inequality or impaired diffusion.
William J.M. Kinnear, James H. Hull
openaire   +1 more source

Venous oxygen saturation

Best Practice & Research Clinical Anaesthesiology, 2014
Early detection and rapid treatment of tissue hypoxia are important goals. Venous oxygen saturation is an indirect index of global oxygen supply-to-demand ratio. Central venous oxygen saturation (ScvO2) measurement has become a surrogate for mixed venous oxygen saturation (SvO2). ScvO2 is measured by a catheter placed in the superior vena cava.
Christiane Hartog, Frank Bloos
openaire   +2 more sources

Oxygen Saturation

Emergency nurse : the journal of the RCN Accident and Emergency Nursing Association
Considerable research has focused on pulse oximeters since their introduction into clinical practice and much of it has been limited to a study of patient hypothermia and movement. The main problems have been vaso- constriction and poor functioning of the light emission diodes in cold environments, as well as operational difficulties.
Dennis G. O'Connell   +2 more
openaire   +3 more sources

Misconceptions in Reporting Oxygen Saturation

Anesthesia & Analgesia, 2007
We describe some misconceptions that have become common practice in reporting blood gas and cooximetry results. In 1980, oxygen saturation was incorrectly redefined in a report of a new instrument for analysis of hemoglobin (Hb) derivatives. Oxygen saturation (sO2) was redefined as the ratio of oxyhemoglobin (O2Hb) to total Hb instead of the ratio of ...
John, Toffaletti, Willem G, Zijlstra
openaire   +2 more sources

Saturated Oxygen Heterocycles

ChemInform, 1997
AbstractFor Abstract see ChemInform Abstract in Full Text.
openaire   +1 more source

Reproducibility of Muscle Oxygen Saturation

International Journal of Sports Medicine, 2011
The present study evaluated the reproducibility of tissue oxygenation in relation to oxygen consumption (VO2) across cycle exercise intensities in a test-retest design. 12 subjects (25.7±2.1 years; 24.7±1.9 kg · m(-2)) twice performed an incremental bicycle exercise protocol, while tissue oxygen saturation (StO2) in the vastus lateralis muscle was ...
C, Thiel   +4 more
openaire   +2 more sources

The Assessment of Nocturnal Oxygen Saturation

Clinical Science, 1983
1. Existing methods of assessing nocturnal episodic hypoxaemia are either insensitive or ignore the majority of the available data. 2. We describe a method of analysis using offline digital processing. A distribution of oxygen saturation (Sao2) with time is produced from all the available data, and subjected to moment analysis to produce
C I, Meanock, A R, Guyatt, G, Cumming
openaire   +2 more sources

Oxygen saturation and cognitive performance

Psychopharmacology, 2002
The purpose of the experiments was to investigate how inhalation of 100% oxygen affected cognitive performance. A test battery was developed that was designed to capture different aspects of cognitive processes, i.e., perception, attention, working memory, long-term memory and prospective memory.
Jan, Andersson   +4 more
openaire   +2 more sources

Home - About - Disclaimer - Privacy