Results 181 to 190 of about 701,661 (299)
ABSTRACT We hereby report a case of a 75‐year‐old patient who developed a large left‐sided hemopneumothorax after a routine dual‐chamber pacemaker insertion. The rare complication was caused by the pacing lead injuring the left internal mammary artery (LIMA) after perforating the right ventricle.
Stuart Stenton +3 more
wiley +1 more source
Zero‐Fluoroscopy Ablation Methods for Atrial Fibrillation: A Systematic Review and Meta‐Analysis
Central illustration. Schematic comparison of conventional fluoroscopy guided ablation (left) and zero fluoroscopy ablation (right), enabled by electroanatomical mapping and intracardiac echocardiography for catheter navigation without X ray. The study selection process is summarized (133 records identified; 12 studies included, total n = 1998 ...
Marwan Shawki +5 more
wiley +1 more source
Cardiac Implantable Electronic Device Infections at a Tertiary Center in Southern Chile (2015-2021): A Retrospective Cohort Study. [PDF]
Landeros A +3 more
europepmc +1 more source
Abstract Background Implantable cardioverter‐defibrillator (ICD) therapy relies on reliable right ventricular leads for pacing, sensing, and defibrillation. The INVICTA DF4 lead is an active‐fixation, quadripolar design intended to optimize implant workflow and long‐term safety and performance. Methods APOLLO was a prospective, multicenter, single‐arm,
Klaus K. Witte +13 more
wiley +1 more source
Tricuspid Regurgitation After Leadless Pacemaker Implantation: The Role of Atrioventricular Synchrony. [PDF]
Seal ZA +7 more
europepmc +1 more source
Magnetic Resonance Imaging Safety in Patients With Conditional Mixed‐Manufacturer Devices
ABSTRACT Background Magnetic resonance imaging (MRI) is a critical diagnostic tool known for its non‐invasive nature and high‐resolution imaging capabilities. However, its safety in patients with cardiac implantable electronic devices (CIEDs), particularly those with mixed‐lead systems, remains a significant clinical concern.
Ryka M. Tashakkor +5 more
wiley +1 more source
ABSTRACT Immune checkpoint inhibitors (ICIs) are now standard of care for most advanced solid tumors. While effective, they are associated with immune‐related adverse events (irAEs), including rare autonomic complications. We present a patient with metastatic lung adenocarcinoma receiving nivolumab and ipilimumab who developed reflex syncope with ...
Ashley Bouzon +3 more
wiley +1 more source
ABSTRACT Introduction Transvenous pacemakers are effective but carry significant short‐ and long‐term complications. Leadless pacemakers were developed to overcome these limitations, however, data in high‐risk patients ineligible for transvenous systems remain limited.
Moshe Katz +7 more
wiley +1 more source
ABSTRACT Introduction Pulmonary vein isolation (PVI) alone achieves modest arrhythmia freedom in persistent atrial fibrillation (PeAF). Cryoballoon ablation (CBA) offers a single‐shot alternative to radiofrequency ablation (RFA) that streamlines procedural workflow.
Harroop Bola +8 more
wiley +1 more source
Expert Consensus Statement: Committee on Implantable Devices and Committee on Social Issues, Japanese Heart Rhythm Society (JHRS) Statement on Remote Monitoring of Cardiac Implantable Electronic Devices. [PDF]
Watanabe E +10 more
europepmc +1 more source

