Results 301 to 310 of about 295,427 (360)
Some of the next articles are maybe not open access.
Emergency Medicine Clinics of North America, 1988
Pacemaker technology has become much more complex in the last ten years. Transcutaneous pacemakers now allow rapid institution of cardiac pacing in the Emergency Department and in the prehospital setting. Permanent pacemakers frequently have dual-chamber pacing and sensing capability as well as multiple programmable modes of operation.
openaire +2 more sources
Pacemaker technology has become much more complex in the last ten years. Transcutaneous pacemakers now allow rapid institution of cardiac pacing in the Emergency Department and in the prehospital setting. Permanent pacemakers frequently have dual-chamber pacing and sensing capability as well as multiple programmable modes of operation.
openaire +2 more sources
Surgical Clinics of North America, 1993
Gastrointestinal pacing has been used to alter motor function and is effective in animal models in modulating gastric emptying, intestinal transit, and absorption. Application of gastrointestinal pacing to disorders of the human stomach and small bowel is an attractive treatment option that may some day become a clinical reality.
J C, Eagon, N J, Soper
openaire +2 more sources
Gastrointestinal pacing has been used to alter motor function and is effective in animal models in modulating gastric emptying, intestinal transit, and absorption. Application of gastrointestinal pacing to disorders of the human stomach and small bowel is an attractive treatment option that may some day become a clinical reality.
J C, Eagon, N J, Soper
openaire +2 more sources
Pacing and Clinical Electrophysiology, 1983
new lead‐electrode for trans‐esophageal pacing of the human heart has been developed. The heart can be paced from the esophagus using currents of the same intensity as those for temporary pacing electrodes. The lead allows the electrodes to be positioned properly in the esophagus with a gastric balloon without use of additional equipment.
H R, Andersen, P, Pless
openaire +3 more sources
new lead‐electrode for trans‐esophageal pacing of the human heart has been developed. The heart can be paced from the esophagus using currents of the same intensity as those for temporary pacing electrodes. The lead allows the electrodes to be positioned properly in the esophagus with a gastric balloon without use of additional equipment.
H R, Andersen, P, Pless
openaire +3 more sources
Left Ventricular Endocardial Pacing/Leadless Pacing
Cardiac Electrophysiology Clinics, 2019Several clinical trials have established the role of cardiac resynchronization therapy in patients with heart failure, impaired left ventricular function and dyssynchrony. Challenges to traditional therapy include coronary sinus anatomy and failure to respond.
Alan, Hanley, E Kevin, Heist
openaire +2 more sources
Cardiac Electrophysiology Clinics, 2018
AbstractPacing induced cardiomyopathy (PICM) is most commonly defined as a drop in left ventricle ejection fraction (LVEF) in the setting of chronic, high burden right ventricle (RV) pacing. Recent data suggest, however, that some individuals may experience the onset of heart failure symptoms more acutely after pacemaker implantation.
Faisal M. Merchant, Suneet Mittal
openaire +3 more sources
AbstractPacing induced cardiomyopathy (PICM) is most commonly defined as a drop in left ventricle ejection fraction (LVEF) in the setting of chronic, high burden right ventricle (RV) pacing. Recent data suggest, however, that some individuals may experience the onset of heart failure symptoms more acutely after pacemaker implantation.
Faisal M. Merchant, Suneet Mittal
openaire +3 more sources
The Annals of Thoracic Surgery, 1979
The basic electrophysiology of temporary and permanent cardiac pacing is reviewed, as are the indications, the types of pacing systems, and the methods of implantation. Recent developments in power sources and leads are described. The mercury-zinc battery is now obsolete and is being replaced by lithium, rechargeable, and isotopic power systems.
openaire +2 more sources
The basic electrophysiology of temporary and permanent cardiac pacing is reviewed, as are the indications, the types of pacing systems, and the methods of implantation. Recent developments in power sources and leads are described. The mercury-zinc battery is now obsolete and is being replaced by lithium, rechargeable, and isotopic power systems.
openaire +2 more sources
Clinics in Chest Medicine, 2018
Diaphragm pacing (DP) is a useful and cost-effective alternative to mechanical ventilation in patients with ventilator-dependent spinal cord injury and central hypoventilation syndrome. Patients with SCI should be carefully screened to assess the integrity of their phrenic nerves.
openaire +2 more sources
Diaphragm pacing (DP) is a useful and cost-effective alternative to mechanical ventilation in patients with ventilator-dependent spinal cord injury and central hypoventilation syndrome. Patients with SCI should be carefully screened to assess the integrity of their phrenic nerves.
openaire +2 more sources
Paced escape-paced capture bigeminy
Heart & Lung, 2005Kirsten, Strapps +2 more
openaire +2 more sources
Pacing and Clinical Electrophysiology, 1997
Patients who have attempted repair of congenital heart disease often develop bradycardia and tachycardias postoperatively. The two dysrhythmias each make treatment of the other more difficult. Pacing is the only modality that addresses both brady‐ and tachycardias, without adversely influencing the other.
openaire +2 more sources
Patients who have attempted repair of congenital heart disease often develop bradycardia and tachycardias postoperatively. The two dysrhythmias each make treatment of the other more difficult. Pacing is the only modality that addresses both brady‐ and tachycardias, without adversely influencing the other.
openaire +2 more sources

