Results 241 to 250 of about 5,889,641 (316)

Automated rapidplan model validation using Eclipse scripting API

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract RapidPlan offers efficiency gains and quality improvements in treatment planning. Prior to its use in the clinic, it requires an extensive validation procedure in which established clinical plans and those generated by the model are compared. The manual iterative nature of this process is resource intensive, as numerous iterations are required
Bradley Beeksma   +2 more
wiley   +1 more source

UR‐cycleGAN: Denoising full‐body low‐dose PET images using cycle‐consistent Generative Adversarial Networks

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study aims to develop a CycleGAN based denoising model to enhance the quality of low‐dose PET (LDPET) images, making them as close as possible to standard‐dose PET (SDPET) images. Methods Using a Philips Vereos PET/CT system, whole‐body PET images of fluorine‐18 fluorodeoxyglucose (18F‐FDG) were acquired from 37 patients to ...
Yang Liu, ZhiWu Sun, HaoJia Liu
wiley   +1 more source

Demonstration of an enhanced dosing pattern for debulking large and bulky unresectable tumors via differential hole‐size spatially fractionated radiotherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose/objective We propose a novel lattice deployment for spatially fractionated radiotherapy (SFRT) treatments. In this approach, a larger diameter high‐dose sphere is centrally placed in the bulky tumor mass and surrounded by smaller diameter high‐dose spheres.
Joshua Misa   +2 more
wiley   +1 more source

Radiotherapy medical physics in the Philippines: A contemporary overview

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose With cancer ranking as the third leading cause of death in the Philippines and a disparity in healthcare resources across regions, this research aimed to assess the state of radiotherapy medical physics in the country. Methodology The study utilized a comprehensive online survey with 94 structured questions answered by 19 clinics ...
John Paul C. Cabahug   +4 more
wiley   +1 more source

Impact of respiratory motion on dose distribution in SIB‐SBRT for lung cancer

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Respiratory motion is a major source of dose uncertainty in lung cancer radiotherapy. The dose distribution of simultaneous integrated boost‐stereotactic body radiotherapy (SIB‐SBRT) is inhomogeneous and is significantly impacted by respiratory motion for lung cancer. The effect of respiratory motion on SIB‐SBRT was investigated with a
Lingling Liu   +7 more
wiley   +1 more source

Home - About - Disclaimer - Privacy