Results 141 to 150 of about 1,752,631 (186)
Some of the next articles are maybe not open access.
Partial coherence interferometry: a novel approach to biometry in cataract surgery
American Journal of Ophthalmology, 1998To compare biometry performed by an enhanced version of dual beam partial coherence interferometry and applanation ultrasound in a prospective study of 85 cataract eyes to improve refractive outcome of cataract surgery due to a more accurate calculation of intraocular lens power.The SRK II formula using ultrasound biometry data was employed.
Oliver Findl +2 more
exaly +3 more sources
American Journal of Ophthalmology, 2017
To compare a new swept-source optical coherence tomography (SSOCT)-based biometer (OA-2000) with the IOLMaster v5.4 (partial-coherence interferometry) and Aladdin (optical low-coherence interferometry) biometers in terms of axial length measurement and failure rate in eyes with cataract.Reliability study.A total of 377 eyes of 210 patients were scanned
Jinhai Huang, Qin-Mei Wang
exaly +3 more sources
To compare a new swept-source optical coherence tomography (SSOCT)-based biometer (OA-2000) with the IOLMaster v5.4 (partial-coherence interferometry) and Aladdin (optical low-coherence interferometry) biometers in terms of axial length measurement and failure rate in eyes with cataract.Reliability study.A total of 377 eyes of 210 patients were scanned
Jinhai Huang, Qin-Mei Wang
exaly +3 more sources
Partial coherence interferometry in a teaching hospital
Journal of Cataract and Refractive Surgery, 2009Partial coherence interferometry (PCI) has an 8% to 22% failure rate for a variety of reasons such as mature cataract, inability to fixate secondary to macular degeneration, tremor, keratopathy, nystagmus, and vitreous hemorrhage. The new composite IOLMaster version 5 software has demonstrated a failure rate of 7.4%, primarily because of posterior ...
Leslie A, Wei +3 more
openaire +2 more sources
Speckle interferometry by partial coherent beam
SPIE Proceedings, 2003By using new theoretical point of view on cross-spectral density function of the field, the propagation of partially coherent beam produce by a plane source is investigated. Then we show, experimentally, the coherence length in the source plane can be measured directly from the far zone intensity distribution.
H. Tajalli, M. Sahrai, D. Jafari
openaire +1 more source
Accuracy and reproducibility of biometry using partial coherence interferometry
Journal of Cataract and Refractive Surgery, 2002To determine whether partial coherence interferometry is comparable to standard contact ultrasonic biometry in accuracy, reproducibility, and ease of use.Academic university practice.In this prospective study, simultaneous biometry was performed in 91 consecutive patients (111 eyes) using partial coherence interferometry (IOLMaster, Zeiss Humphrey ...
Rafe, Connors +2 more
openaire +2 more sources
Off‐axis partial coherence interferometry in myopes and emmetropes
Ophthalmic and Physiological Optics, 2012Abstract Purpose This study describes the axial and peripheral dimensions of myopic and emmetropic eyes in a wide range of retinal locations using a non‐contact optical biometer (Zeiss IOLM aster) based upon the principle of ...
Asieh, Ehsaei +3 more
openaire +2 more sources
Eye-length measurement by interferometry with partially coherent light
Optics Letters, 1988With a multimode semiconductor laser we have been able to measure the optical length of the eye within a precision of 0.03 mm. A first series of in vivo measurements acoustically determined eye length.
A F, Fercher, K, Mengedoht, W, Werner
openaire +2 more sources
Immersion A-scan compared with partial coherence interferometry
Journal of Cataract and Refractive Surgery, 2002To compare 2 methods of axial length measurement, immersion ultrasonography and partial coherence interferometry, and to elucidate surgical outcomes based on immersion measurements.Oregon Eye Institute, Eugene, Oregon, USA.Axial length measurements in 50 cataractous eyes were obtained by optical biometry (IOLMaster, Zeiss Humphrey Systems) and ...
Mark, Packer +4 more
openaire +2 more sources
Repeat-Pass SAR Interferometry With Partially Coherent Targets
IEEE Transactions on Geoscience and Remote Sensing, 2012By means of the permanent scatterer (PS) technique, repeated spaceborne synthetic aperture radar (SAR) images with relatively low resolution (about 25 m × 5 m for the European Remote Sensing (ERS) and Envisat satellites) can be used to estimate the displacement (1-mm precision) and 3-D location (1-m precision) of targets that show an unchanged ...
Daniele Perissin, Teng Wang 0001
openaire +1 more source
Intraocular Lens Power Measured by Partial Coherence Interferometry
Optometry and Vision Science, 2012ABSTRACT Purpose To compare the accuracy of the intraocular lens (IOL) power calculation of the Zeiss IOLMaster versus conventional automated keratometry and contact acoustic biometry after personalized optimization. Methods
Yi-Ting, Hsieh, I-Jong, Wang
openaire +2 more sources

