Results 181 to 190 of about 2,611 (204)
Some of the next articles are maybe not open access.

Improved prediction of intraocular lens power using partial coherence interferometry

Journal of Cataract and Refractive Surgery, 2001
To evaluate the feasibility of using a new optical biometry technique, dual-beam partial coherence interferometry (PCI), to improve intraocular lens (IOL) power prediction in cataract surgery.Department of Ophthalmology, Vienna General Hospital, and Institute of Medical Physics, University of Vienna, Vienna, Austria.Preoperative axial length (AL) data ...
O, Findl   +5 more
openaire   +2 more sources

High precision biometry of pseudophakic eyes using partial coherence interferometry

Journal of Cataract and Refractive Surgery, 1998
To investigate the applicability of the scanning version of dual-beam partial coherence interferometry (PCI) for measuring the anterior segment and axial length of pseudophakic eyes in a clinical setting and to determine the achievable precision with this biometry technique.Department of Ophthalmology, Vienna General Hospital, and Institute of Medical ...
O, Findl   +4 more
openaire   +2 more sources

A Partial Coherent Interferometry for measuring the thickness of a dynamic liquid sheet

International Journal of Multiphase Flow, 2019
Abstract This work presents a non-invasive technique, Partial Coherent Interferometry, for measuring the thickness distribution of a dynamic liquid sheet. It utilizes the linear relationship between the degree of coherence and the optical path difference to determine the thickness of the sheet. In an interferometer using a partial coherent laser, the
Weixiao Shang, Jun Chen
openaire   +1 more source

Biometry of cataractous eyes using partial coherence interferometry

Journal of Cataract and Refractive Surgery, 2002
To evaluate the clinical feasibility of the prototype version of a commercial partial coherence interferometry instrument (axial length measurement, ALM, Carl Zeiss Jena) for noninvasive, high-precision biometry in cataractous eyes.Department of Ophthalmology, Vienna General Hospital, and Institute of Medical Physics, University of Vienna, Austria.The ...
Barbara, Kiss   +6 more
openaire   +2 more sources

Comparison of AL-Scan and IOLMaster 500 Partial Coherence Interferometry Optical Biometers

Journal of Refractive Surgery, 2016
PURPOSE: To investigate agreement between the ocular biometry measurements provided by a newer optical biometer, the AL-Scan (Nidek Co, Ltd., Gamagori, Japan) and those provided by the IOLMaster 500 (Carl Zeiss Meditec, Jena Germany), which are both based on partial coherence interferometry ...
Kenneth J, Hoffer, Giacomo, Savini
openaire   +2 more sources

Anterior segment changes with age and during accommodation measured with partial coherence interferometry

Journal of Cataract and Refractive Surgery, 2007
To evaluate anterior segment alterations with age and during accommodation in different age groups.Department of Ophthalmology, Medical and Health Science Center, University of Debrecen, Debrecen, Hungary.Fifty-three subjects (101 normal eyes) were enrolled in this study and divided into 3 age groups: younger than 30 years (Group 1), between 31 years ...
Alexis, Tsorbatzoglou   +4 more
openaire   +2 more sources

Comparison of ultrasound pachymetry and partial coherence interferometry in the measurement of central corneal thickness

Journal of Cataract and Refractive Surgery, 2002
To compare central corneal thickness (CCT) measurements obtained with 3 ultrasound pachymeters and with partial coherence interferometry (PCI) and evaluate the effect of repeated contact by a pachymetry probe on corneal thickness.Department of Ophthalmology, University of Vienna, Vienna, Austria.Central corneal thickness was measured in 20 eyes of 20 ...
Georg, Rainer   +6 more
openaire   +2 more sources

Pseudophakic accommodation and pseudoaccommodation under physiological conditions measured with partial coherence interferometry

Journal of Cataract and Refractive Surgery, 2006
To distinguish pseudophakic accommodation from pseudoaccommodation by measuring the physiologically and pharmacologically induced anterior chamber depth (ACD) shifts.Department of Ophthalmology, University of Debrecen, Debrecen, Hungary.This study comprised 100 pseudophakic eyes of 79 patients.
Alexis, Tsorbatzoglou   +3 more
openaire   +2 more sources

Partially coherent illumination in lateral shearing interferometry

2018
This thesis discusses the influence of a special spatially extended light source in lateral shearing interferometry, both in the two-beam case and for speckle interferometry. In particular, the use of diffractive elements is emphasized, whereby intrinsic errors of the experimental setups can be kept low and at the same time a high degree of flexibility
openaire   +1 more source

Home - About - Disclaimer - Privacy