Results 11 to 20 of about 41,685 (161)
Development and verification of a software tool for the acoustic location of partial discharge in a power transformer [PDF]
This paper discusses the development and verification of software tool for determining the location of partial discharge in a power transformer with the acoustic method.
Polužanski Vladimir +3 more
doaj +1 more source
Partial Discharge Behaviour of a Protrusion in Gas-Insulated Systems under DC Voltage Stress
High reliability, independence from environmental conditions, and the compact design of gas-insulated systems will lead to a wide application in future high voltage direct current (HVDC) transmission systems.
Thomas Götz +2 more
doaj +1 more source
One of the main tools for monitoring the condition of high voltage equipment is the measurement of partial discharges (PD). The electromagnetic (EM) radiation originated from this degradation phenomenon can be captured by various types of ultra‐high ...
Jorge A. Ardila‐Rey +5 more
doaj +1 more source
Gas-insulated switchgear malfunctions during power system operation may occur due to electrical, thermal, or human errors in the manufacturing process. The leading causes of insulation deterioration of gas-insulated switchgear are discharging along the ...
I-Hua Chung, Yu-Hsun Lin
doaj +1 more source
Partial discharge (PD) detection is used to evaluate the insulation status of high‐voltage equipment. The most challenging aspect of traditional PD recognition is extracting features from the discharge signal.
Feng‐Chang Gu
doaj +1 more source
Study on the Measurement Technique and Judgment Procedure of Ultrasonic Corona Imaging Equipment
Corona discharge is a phenomenon wherein gas on the surface of electrical equipment is ionised. Severe ionisation can lead to insulation breakdown and cause equipment damage.
Ja-Yoon Kang +4 more
doaj +1 more source
Improvement of partial discharge resistance of polypropylene under AC voltage by blending elastomer
This paper reports on the partial discharge (PD) erosion characteristics of polypropylene (PP)/elastomer blends where ethylene‐octene copolymer elastomer (EOC) and propylene‐based elastomer are involved.
Yu Gao +6 more
doaj +1 more source
Inductively coupled probe for the measurement of partial discharges [PDF]
Partial discharges are a transient phenomena whose measurement is remarkably important for electrical equipment diagnosis and maintenance. These discharges appear in the measurement circuit as very narrow current pulses of some nanoseconds. Therefore, discharge pulse detection is a particularly difficult problem, especially because they are superposed ...
Robles Muñoz, Guillermo +3 more
openaire +3 more sources
Overview and Partial Discharge Analysis of Power Transformers: A Literature Review
The high voltage power transformer is the critical element of the power system, which requires continuous monitoring to prevent sudden catastrophic failures and to ensure an uninterrupted power supply.
Md Rashid Hussain +2 more
doaj +1 more source
Performance of Reference Partial Discharge Measurement System [PDF]
The work reported here has received support from the EMPIR programme co-financed by the Participating States and from the European Union's Horizon 2020 research and innovation programme.
MEREV, Ahmet +3 more
openaire +3 more sources