Evaluation of Uncertainty in Partial Discharge Measurement: A Case Study
ISO/IEC 17025:2017 recommends all accredited laboratories under this standard, performing testing and calibration, shall identify and evaluate the contributions to the uncertainty of their measurements.
Asif Islam +5 more
doaj +1 more source
Development of a High-Speed Data Acquisition Card for Partial Discharge Measurement
This study Development a high-speed data acquisition (DAQ) device by using AD9226 analog-to-digital converters, a field programmable gate array, and an ARM Cortex-A8 microprocessor for a self-designed synchronous 6-channel high-speed DAQ card that was ...
Feng-Chang Gu +4 more
doaj +1 more source
Study of using three dimensional printer for EDM electrode fabrication [PDF]
In this study, Cu-Al2O3 powder was prepared using ball mill and used separately for powder metallurgy (PM) and Three Dimensional Printer (3DP) application to fabricate electrode for electrical discharge machining (EDM).
Hassan, Noor Haslyena
core
Data management of on-line partial discharge monitoring using wireless sensor nodes integrated with a multi-agent system [PDF]
On-line partial discharge monitoring has been the subject of significant research in previous years but little work has been carried out with regard to the management of on-site data.
M. Judd +6 more
core +2 more sources
Functional Connectivity Linked to Cognitive Recovery After Minor Stroke
ABSTRACT Objective Patients with minor stroke exhibit slowed processing speed and generalized alterations in functional connectivity involving frontoparietal cortex (FPC). The pattern of connectivity evolves over time. In this study, we examine the relationship of functional connectivity patterns to cognitive performance, to determine ...
Vrishab Commuri +7 more
wiley +1 more source
ABSTRACT Objective Accurate localization of epileptogenic tubers (ETs) in patients with tuberous sclerosis complex (TSC) is essential but challenging, as these tubers lack distinct pathological or genetic markers to differentiate them from other cortical tubers.
Tinghong Liu +11 more
wiley +1 more source
AN ELECTRICAL SYSTEM FOR TESTING CROSS-LINKED POLYETHYLENE POWER CABLES OF ALL VOLTAGE CLASSES
The paper introduces a design solution for building a test system for measurement of partial discharge and detection of breakdown spots via voltage resonance.
V.P. Karpushenko +3 more
doaj
INFLUENCE OF PARAMETERS OF THE SCHEME OF REGISTRATION ON AMPLITUDE AND SHAPE OF PARTIAL DISCHARGE
In this paper reports on computer modeling of discharge processes in dielectric Multisim environment. The simulation was performed for partial discharges measuring circuit with a current sensor in the chain of isolation grounding.
A. M. Ba Boraik +2 more
doaj +1 more source
Time domain analysis of switching transient fields in high voltage substations [PDF]
Switching operations of circuit breakers and disconnect switches generate transient currents propagating along the substation busbars. At the moment of switching, the busbars temporarily acts as antennae radiating transient electromagnetic fields within ...
Judd, M.D., Musa, B.U., Siew, W.H.
core
Classification of multiple electromagnetic interference events in high-voltage power plant [PDF]
This paper addresses condition assessment of electrical assets contained in high voltage power plants. Our work introduces a novel analysis approach of multiple event signals related to faults, and which are measured using Electro-Magnetic Interference ...
Boreham, Philip +5 more
core +2 more sources