Results 261 to 270 of about 169,131 (312)
Polarized Phase-Sensitive Fluorescence-Image Correlation Spectroscopy. [PDF]
Clayton AHA.
europepmc +1 more source
Particle size distribution and concentration of Intralipid<sup>®</sup> 20. [PDF]
Shahsavari M +5 more
europepmc +1 more source
3D Single-Virus Tracking: Advances in Methodology and Labeling Strategies Towards Probing the Virus-Epithelium Interaction. [PDF]
Lin Y, Lin H, Yu D, Welsher K.
europepmc +1 more source
Advanced Quality and Comparability Assessment of mRNA-Loaded Lipid Nanoparticles: Absolute Size Distribution Profiles and Structure from AF4-Coupled Light and X-ray Scattering Measurements. [PDF]
Kolb B +9 more
europepmc +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
2020
Abstract The book describes the fundamentals of particle detectors in their different forms as well as their applications, presenting the abundant material as clearly as possible and as deeply as needed for a thorough understanding.
Hermann Kolanoski, Norbert Wermes
openaire +1 more source
Abstract The book describes the fundamentals of particle detectors in their different forms as well as their applications, presenting the abundant material as clearly as possible and as deeply as needed for a thorough understanding.
Hermann Kolanoski, Norbert Wermes
openaire +1 more source
2023
Many of the particle detectors developed are gaseous based on ionization. The semiconductor and scintillation detectors are the most typical and cast-off, but other, entirely diverse ideologies have also been functional, like Cerenkov light and transition radiation.
Ritesh Kohale +2 more
openaire +1 more source
Many of the particle detectors developed are gaseous based on ionization. The semiconductor and scintillation detectors are the most typical and cast-off, but other, entirely diverse ideologies have also been functional, like Cerenkov light and transition radiation.
Ritesh Kohale +2 more
openaire +1 more source
2008
Elementary particles can be identified through various techniques, depending on the purpose of the measurement and which relevant quantities, such as time, energy, and spatial coordinates, have to be measured. Detectors cover the measurement of energies spanning from the very low to the highest energies observed in cosmic rays.
Claus Grupen, Boris Shwartz
openaire +1 more source
Elementary particles can be identified through various techniques, depending on the purpose of the measurement and which relevant quantities, such as time, energy, and spatial coordinates, have to be measured. Detectors cover the measurement of energies spanning from the very low to the highest energies observed in cosmic rays.
Claus Grupen, Boris Shwartz
openaire +1 more source
Spark detectors for charged particles
Uspekhi Fizicheskih Nauk, 1963INTRODUCTION I. Spark Counters 429 1. General Description of Spark Counters 429 2. Counting Characteristic 429 3. Counter Efficiency 431 4. Time Characteristics of Counters 431 5. Accuracy of Particle Trajectory Coordinate Measurement 432 II. Triggered Spark Counters 435 6. Operating Principle of Triggered Spark Counters 435 7.
M I Daĭon, G A Leksin
openaire +1 more source

