Results 101 to 110 of about 34,619 (164)
Bridged Conductive Nanofibrous Membrane Overcoming the Porosity-Conductivity Trade-Off for Electrothermal Air Purification. [PDF]
Yao X +10 more
europepmc +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Quasi-passive filter for harmonic filtering
Electric Power Systems Research, 2008To overcome the limitations of conventional shunt passive filters, a quasi-passive filter has been proposed in this paper. It comprises of a parallel and series tuned LC tank circuit. Unlike the conventional shunt passive filter, the quasi-passive filter utilizes a large value ac capacitor.
R. Mahanty, A.K. Kapoor
openaire +1 more source
IETE Journal of Research, 1976
A critical study of various types of passive notch filters is made. The distributed parameter notch filters are found to be superior in performance as compared to the lumped RC and lumped-distributed types. The frequency response curves indicate that tapering in distributed notch filters improves the notch selectivity.
M. J. R. Khan +2 more
openaire +1 more source
A critical study of various types of passive notch filters is made. The distributed parameter notch filters are found to be superior in performance as compared to the lumped RC and lumped-distributed types. The frequency response curves indicate that tapering in distributed notch filters improves the notch selectivity.
M. J. R. Khan +2 more
openaire +1 more source
IEEE Journal of Solid-State Circuits, 1981
Novel passive recursive CCD bandpass filters have been realized using standard two-level-polysilicon gate NMOS technology. A Chebyshev bandpass (w/SUB rel,/ /SUB 3/ /SUB dB/=3.1 percent) and a fully integrated CCD signal filter with an extremely narrow 3 dB bandwidth of 97 Hz (Q=1350) at 131.85 kHz center frequency were implemented by means of cascaded
R. Schreiber +4 more
openaire +1 more source
Novel passive recursive CCD bandpass filters have been realized using standard two-level-polysilicon gate NMOS technology. A Chebyshev bandpass (w/SUB rel,/ /SUB 3/ /SUB dB/=3.1 percent) and a fully integrated CCD signal filter with an extremely narrow 3 dB bandwidth of 97 Hz (Q=1350) at 131.85 kHz center frequency were implemented by means of cascaded
R. Schreiber +4 more
openaire +1 more source
Multi-output passive digital filters
2004 IEEE Electro/Information Technology Conference, 2004In this paper, a new family of four multi-output second-order passive digital filters constructed from four passive digital two-ports are presented. The conditions for passivity in a passive digital two-port are first defined. Four passive two-ports are introduced, their passivity and stability constraints on coefficients, and pseudopower expressions ...
openaire +1 more source

