A Scaling Analysis for a General Passive Heat Removal System

Volume 6A: Thermal-Hydraulics and Safety Analyses, 2018
Passive cooling technology has been adopted by more and more designs of advanced PWRs, because of its benefits to simplifying the design of safety systems, to reducing mis-operations performed by operators during accidents, and to cutting the cost of operation and maintenance.
Li Wei   +3 more
openaire   +1 more source

Heat Transfer Modeling of the LSTF Passive Residual Heat Removal System

Nuclear Engineering, 1997
Abstract Data from a model Passive Residual Heat Removal (PRHR) system operated in the ROSA facility during simulated loss-of-coolant accidents were compared with heat transfer calculations using a one-dimensional steady-state computer model. The calculations agree reasonably well with the data.
Glenn E. McCreery   +4 more
openaire   +1 more source

Aerosol Removal by a Heat Exchanger of Passive Containment Cooling System

Volume 2: Nuclear Fuels, Research, and Fuel Cycle; Nuclear Codes and Standards; Thermal-Hydraulics, 2021
Abstract The aerosol removal mechanism and capacity related to passive containment cooling system (PCS) for PWR reactors during the severe accident is an important and interesting topic among researchers, which can enhance the natural removal of suspended aerosols, reducing the radioactivity that may leak into the environment.
Yangyang Liang   +4 more
openaire   +1 more source

Design and modeling of the passive residual heat removal system for VVERs

Annals of Nuclear Energy, 2016
Abstract The results and effects of the Fukushima Daiichi accident show that the passive safety systems, which require no user input in order to operate, are very significant in nuclear industry. Even after stopping the reactor, heat dissipation remains a primary concern.
Hüseyin Ayhan, Cemal Niyazi Sökmen
openaire   +1 more source

A Numerical Research on the Heat Transfer Process for a General Passive Heat Removal System

Volume 6: Thermal-Hydraulics, 2017
A code module for simulating a general passive heat removal system composed of an elevated water tank, a heat exchanger and pipes connecting them is developed in this paper. Then, a typical heat transfer process in this heat removal system is calculated. According to the simulation results, the flash shows the most important impact of the heat transfer
Li Wei, Liu Zhuo, Guo Qiang, Yuan Yidan
openaire   +1 more source

Transient Analysis of Passive Decay Heat Removal System for CEFR

Volume 2: Plant Systems, Construction, Structures and Components; Next Generation Reactors and Advanced Reactors, 2013
A passive decay heat removal system (DHRS) has been installed on Chinese Experimental Fast Reactor (CEFR). To well predict the thermal-hydraulics behavior of DHRS in transient, an integrated model has been developed for CEFR by using OASIS code. The model included the main thermal transfer system and DHRS circuit.
H. Qian, Z. Li, L. Ren
openaire   +1 more source

Design and analysis of a new passive residual heat removal system

Nuclear Engineering and Design, 2016
Abstract The inherent safety functions will mitigate the consequences of the accidents, and it can be accomplished through the passive safety systems which employed in the typical pressurized water reactor (PWR). In this paper, a new passive residual heat removal system (PRHRS) is designed for a typical nuclear power plant.
Xing Lv   +3 more
openaire   +1 more source

Analysis of Passive Heat Removal System by ANSYS CFX software

2018 19th International Scientific Conference on Electric Power Engineering (EPE), 2018
In the current study, the model of Passive Heat Removal System (PHRS) through SG (steam-generator) was developed for computational fluid dynamics (CFD) analysis. During work there was done three main tasks, which are creating geometrical form of PHRS, meshing of model to achieve a better analysis of thermo-hydraulic phenomena and creating domains for ...
Taron Petrosyan   +2 more
openaire   +1 more source

Experimental Study on Secondary Passive Residual Heat Removal System

2017
The secondary passive residual heat removal system, which is one of several passive safety systems, is designed to enhance the safety of the reactor core. Experiments on transient and steady state natural circulation performance of the secondary passive residual heat removal system had been performed by using the high temperature, high pressure, and ...
Haiyan Xu   +4 more
openaire   +1 more source

Heat Transfer Analysis of the Passive Residual Heat Removal System in ROSA/AP600 Experiments

Nuclear Technology, 1998
The passive residual heat removal (PRHR) system in the Westinghouse AP600 advanced passive reactor design is a natural-circulation-driven heat exchanger cooled by the water in the in-containment refueling water storage tank (IRWST). During the experiments, which simulated small-break loss-of-coolant accidents in the AP600 reactor using the ROSA-V Large-
Taisuke Yonomoto   +2 more
openaire   +1 more source