Results 221 to 230 of about 49,441 (308)

Biolipid Film‐Fused Electrochemiluminescence for Multipurpose In Situ Bioassays

open access: yesAdvanced Science, EarlyView.
An ECL‐emissive, membrane‐interactive scaffold was fabricated, and facilely fused with natural and non‐native phospholipids into multifactorial mimicries of cytomembranes and vesicles for in vitro representative membrane‐process probing. Such a biointerface‐based, state‐sensitive ECL paradigm not only pinpointed proximal phenomena, including channeling
Jialiang Chen   +9 more
wiley   +1 more source

Sustainable Materials Design With Multi‐Modal Artificial Intelligence

open access: yesAdvanced Science, EarlyView.
Critical mineral scarcity, high embodied carbon, and persistent pollution from materials processing intensify the need for sustainable materials design. This review frames the problem as multi‐objective optimization under heterogeneous, high‐dimensional evidence and highlights multi‐modal AI as an enabling pathway.
Tianyi Xu   +8 more
wiley   +1 more source

Spontaneous Non‐Catalyzed Molecular Reactions and Interactions in the Human Body: Biomedical Implications

open access: yesAdvanced Science, EarlyView.
ABSTRACT The human body functions as a natural reactor for a vast network of chemical and biological reactions and physical interactions among small molecules, proteins, cells, and numerous other components. These reactions/interactions are essential for maintaining normal physiological functions.
Yuhao Cai, Chao Zhao
wiley   +1 more source

Polarization‐Enabled Piezoelectric Tellurium–Selenium (TexSe1–x) Thin Films for Memory Switching and Artificial Synaptic Functions

open access: yesAdvanced Science, EarlyView.
Here, we demonstrate and investigate polarization‐enabled electromechanical responses in cryogenic physical vapor deposition (cryogenic PVD)‐deposited TexSe1‐x thin films, a tellurium‐based compound with a tunable bandgap and enhanced non‐centrosymmetry.
Chia‐Chen Chung   +16 more
wiley   +1 more source

Use of preload responsiveness tests in pediatric intensive care units: A nationwide prospective clinical practice analysis. [PDF]

open access: yesAnn Intensive Care
Gotchac J   +11 more
europepmc   +1 more source

Friend, Not Foe: Lowered Tissue Reactivity to Long‐Term Polyimide Implants

open access: yesAdvanced Science, EarlyView.
The choice of optimal neural probe designs remains a major challenge in the field of neurotechnology. This study investigated the biocompatibility of several probe variations, including material, thickness, width, and implantation strategy. It highlights the clear advantage of soft polyimide probes over stiff silicon probes for better device ...
Corinne Orlemann   +11 more
wiley   +1 more source

Real-Time Ultrasound Elastography in Multiple Sclerosis Spasticity: Comparison with Clinical and Neurophysiological Measures. [PDF]

open access: yesJ Clin Med
Bakola E   +7 more
europepmc   +1 more source

One‐Step, High‐Removal‐Rate and Low‐Damage Chemical Mechanical Polishing of InP Enabled by Hydrolysis Activated PF6− with In Situ Fluoride Passivation

open access: yesAdvanced Science, EarlyView.
In this work, we propose a CMP method for InP using NH4PF₆, which hydrolyzes under In3+ catalysis to form reactive species. These convert InP into low‐binding‐energy fluorides, facilitating removal and dissolution. The process delivers high material removal rates, smooth surfaces, and fluorine passivation that lowers defect density and improves ...
Shigong Fu   +5 more
wiley   +1 more source

Home - About - Disclaimer - Privacy