Results 161 to 170 of about 2,177 (208)
Some of the next articles are maybe not open access.
Passive micromixer with break-up obstructions
SPIE Proceedings, 2006In this paper, we report on design and fabrication of a passive microfluidic mixer capable of mixing at low Reynolds numbers ( Re ). Passive mixers typically use channel geometry to mix fluids, and many previously reported designs that work only at moderate to high Reynolds numbers and are often difficult to fabricate.
Ali Asgar S. Bhagat +2 more
openaire +1 more source
Frequency-Controlled Wireless Passive Thermopneumatic Micromixer
Journal of Microelectromechanical Systems, 2017This paper reports a novel wireless control of a thermopneumatic zigzag micromixer achieved by selectively activating two passive wireless heaters enabled by an external radiofrequency magnetic field. The two heaters, which are designed to have different resonant frequency (f r ) values of 100 and 130 MHz, are selectively activated by modulating the ...
Marwan Nafea +3 more
openaire +1 more source
Recirculating, passive micromixer with a novel sawtooth structure
Lab Chip, 2006A microfluidic device capable of recirculating nano to microlitre volumes in order to efficiently mix solutions is described. The device consists of molded polydimethyl siloxane (PDMS) channels with pressure inlet and outlet holes sealed by a glass lid. Recirculation is accomplished by a repeatedly reciprocated flow over an iterated sawtooth structure.
Kevin P, Nichols +2 more
openaire +2 more sources
Passive Vortex Micromixers Utilizing Hybrid Laminations
Volume 13: Nano-Manufacturing Technology; and Micro and Nano Systems, Parts A and B, 2008This theoretical investigation analyzed the three-dimensional momentum and mass transfer characteristics arising from the multiple inlets and single outlet in micro chamber which consists of a right square prism, an octagonal prism or a cylinder. The effects of various geometric parameters, inlet velocities, and the types of lamination on the mixing ...
Jyh-Jian Chen +3 more
openaire +1 more source
Mathematical Analysis of a Spiral Passive Micromixer
2021This research work possesses a mathematical analysis and comparison of mixing performance and flow behavior inside microchannels with different geometries: simple T shape and spiral/helical shape. The flow analysis is carried out using Navier–Stokes equations, and mixing performance of two fluids, namely water and dye, is numerically calculated.
Syed Farhan Javed +2 more
openaire +1 more source
Passive Micromixer with Sharp Edges: Simulation and Optimization
2020 21st International Conference on Thermal, Mechanical and Multi-Physics Simulation and Experiments in Microelectronics and Microsystems (EuroSimE), 2020In this study, the mixing performances of passive micromixers with sharp edges were investigated. First, a validation study was conducted by using experimental results on a passive micromixers in the literature. The arrangement of the triangle obstacles was then changed to optimize the mixing performance.
Moein Talebian Gevari +2 more
openaire +1 more source
A flexible layout design method for passive micromixers
Biomedical Microdevices, 2012This paper discusses a flexible layout design method of passive micromixers based on the topology optimization of fluidic flows. Being different from the trial and error method, this method obtains the detailed layout of a passive micromixer according to the desired mixing performance by solving a topology optimization problem.
Yongbo, Deng +5 more
openaire +2 more sources
Staggered passive micromixers with fractal surface patterning
Journal of Micromechanics and Microengineering, 2006We present a procedure for inducing chaotic mixing based on a non-periodic patterning of the walls making use of the Weierstrass fractal function to generate the locations for the grooves. We show the numerical analysis of flow in three different geometries generated with the Weierstrass function and compare the results with a fourth geometry, quite ...
Marco Camesasca +2 more
openaire +1 more source
Investigation of Mixing Performance in Passive Micromixers
Industrial & Engineering Chemistry Research, 2016This work is focused on the mixing performance in passive microchannels. Experiments are performed to investigate the effect of inlet mixing angle and surface wettability on the micromixing efficiency in micromixers. The iodate–iodide testing reaction and a micro particle image velocimetry (micro-PIV) system are adopted to characterize the micromixing ...
Weipeng Zhang +4 more
openaire +1 more source
A passive micromixer for enzymatic digestion of DNA
Microelectronic Engineering, 2014A passive micromixer with zigzag geometry is fabricated using FPC technology.The total length of the micromixer is estimated by simulation.The micromixer is evaluated with a DNA digestion process with restriction enzymes.Simultaneous mixing of enzymes with DNA and DNA digestion is achieved in 2.5min.
V.E. Papadopoulos +7 more