Results 21 to 30 of about 16,412,614 (252)

Evaluation of Dosimetry Check software for IMRT patient‐specific quality assurance [PDF]

open access: yesJournal of Applied Clinical Medical Physics, 2015
The purpose of this study is to evaluate the use of the Dosimetry Check system for patient‐specific IMRT QA. Typical QA methods measure the dose in an array dosimeter surrounded by homogenous medium for which the treatment plan has been recomputed. With the Dosimetry Check system, fluence measurements acquired on a portal dosimeter is applied to the ...
Narayanasamy, Ganesh   +4 more
openaire   +2 more sources

Application of statistical process control methods in the retrospective review and design of patient-specific quality assurance processes

open access: yes, 2022
Poster describing application of control charts to determine appropriate tolerance limits for pre-treatment patient-specific quality assurance of external beam radiotherapy ...
Yu, Liting   +3 more
core   +1 more source

Applications of machine and deep learning to patient‐specific IMRT/VMAT quality assurance [PDF]

open access: yesJournal of Applied Clinical Medical Physics, 2021
AbstractIn order to deliver accurate and safe treatment to cancer patients in radiation therapy using advanced techniques such as intensity modulated radiation therapy (IMRT) and volumetric‐arc radiation therapy (VMAT), patient specific quality assurance (QA) should be performed before treatment.
Alexander F. I. Osman, Nabil Maalej
openaire   +2 more sources

4089 Clinical Implementation of Monte Carlo Dose Calculation for Patient-Specific Radiotherapy Quality Assurance

open access: yesJournal of Clinical and Translational Science, 2020
OBJECTIVES/GOALS: The Monte Carlo dose calculation method is often considered the “gold standard” for patient dose calculations and can be as radiation dose measurements.
Holly Marie Parenica   +6 more
doaj   +1 more source

Deep Hybrid Learning Prediction of Patient-Specific Quality Assurance in Radiotherapy: Implementation in Clinical Routine

open access: yesDiagnostics, 2023
Background: Arc therapy allows for better dose deposition conformation, but the radiotherapy plans (RT plans) are more complex, requiring patient-specific pre-treatment quality assurance (QA). In turn, pre-treatment QA adds to the workload. The objective
Noémie Moreau   +7 more
doaj   +1 more source

Treatment plan prescreening for patient-specific quality assurance measurements using independent Monte Carlo dose calculations

open access: yesFrontiers in Oncology, 2022
PurposeThis study proposes a method to identify plans that failed patient-specific quality assurance (QA) and attempts to establish a criterion to prescreen treatment plans for patient-specific QA measurements with independent Monte Carlo dose ...
Yuan Xu   +7 more
doaj   +1 more source

Development of Dosimetric Verification System for Patient-Specific Quality Assurance of High-Dose-Rate Brachytherapy

open access: yesFrontiers in Oncology, 2021
Purpose: The aim of this study was to develop a dosimetric verification system (DVS) using a solid phantom for patient-specific quality assurance (QA) of high-dose-rate brachytherapy (HDR-BT).Methods: The proposed DVS consists of three parts: dose ...
Sang-Won Kang   +18 more
doaj   +1 more source

Prediction of portal dosimetry quality assurance results using log files-derived errors and machine learning techniques

open access: yesFrontiers in Oncology, 2023
ObjectiveThis work aims to use machine learning models to predict gamma passing rate of portal dosimetry quality assurance with log file derived features.
Kah Seng Lew   +6 more
doaj   +1 more source

Clinical evaluation of an anatomy‐based patient specific quality assurance system

open access: yesJournal of Applied Clinical Medical Physics, 2014
The Delta4DVH Anatomy 3D quality assurance (QA) system (ScandiDos), which converts the measured detector dose into the dose distribution in the patient geometry was evaluated. It allows a direct comparison of the calculated 3D dose with the measured back‐projected dose.
Hauri, P   +5 more
openaire   +4 more sources

Analysis of dose comparison techniques for patient‐specific quality assurance in radiation therapy [PDF]

open access: yesJournal of Applied Clinical Medical Physics, 2019
AbstractPurposeGamma evaluation is the most commonly used technique for comparison of dose distributions for patient‐specific pretreatment quality assurance in radiation therapy. Alternative dose comparison techniques have been developed but not widely implemented. This study aimed to compare and evaluate the performance of several previously published
Yu, Liting   +6 more
openaire   +5 more sources

Home - About - Disclaimer - Privacy