Results 21 to 30 of about 85,512 (248)
Feasibility study of structural similarity index for patient-specific quality assurance. [PDF]
AbstractBackgroundThe traditional gamma evaluation method combines dose difference (DD) and distance‐to‐agreement (DTA) to assess the agreement between two dose distributions. However, while gamma evaluation can identify the location of errors, it does not provide information about the type of errors.PurposeThe purpose of this study is to optimize and ...
Lee JC, Park HW, Kang YN.
europepmc +3 more sources
Feasibility of a 3D-printed anthropomorphic patient-specific head phantom for patient-specific quality assurance of intensity-modulated radiotherapy. [PDF]
This study evaluated the feasibility of utilizing a 3D-printed anthropomorphic patient-specific head phantom for patient-specific quality assurance (QA) in intensity-modulated radiotherapy (IMRT).
Ji Woon Yea +8 more
doaj +1 more source
A sophisticated machine of radiotherapy treatment process follows the complexity of the quality assurance (QA) measurement. Non-measurement QA becomes one of the solutions to reduce the medical physicists’ workload.
Akbar Azzi +2 more
doaj +1 more source
VALIDATION OF COMPASS FOR PRE-TREATMENT PATIENT-SPECIFIC QUALITY ASSURANCE
Aim: Purpose of study is to validate COMPASS 3D patient specific quality-assurance software with Monaco treatment planning system (TPS) for routine quality assurance. Materials & methods: Purpose is to test the MLC modelling in COMPASS software, using Elekta Express QA package contains eight QA fields as follows (i) 10x10 (ii) 20x20 (iii) 3ABUT ...
Seema Sharma +8 more
openaire +2 more sources
Comparing log file to measurement-based patient-specific quality assurance
Abstract Recent technological advances have allowed the possibility of performing patient-specific quality assurance (QA) without time-intensive measurements. The objectives of this study are to: 1) compare how well the log file-based Mobius QA system agrees with measurement-based QA methods (ArcCHECK and portal dosimetry, PD) in passing and ...
Li Ting Chan +9 more
openaire +2 more sources
Applications of machine and deep learning to patient‐specific IMRT/VMAT quality assurance [PDF]
AbstractIn order to deliver accurate and safe treatment to cancer patients in radiation therapy using advanced techniques such as intensity modulated radiation therapy (IMRT) and volumetric‐arc radiation therapy (VMAT), patient specific quality assurance (QA) should be performed before treatment.
Alexander F. I. Osman, Nabil Maalej
openaire +2 more sources
Evaluation of Dosimetry Check software for IMRT patient‐specific quality assurance [PDF]
The purpose of this study is to evaluate the use of the Dosimetry Check system for patient‐specific IMRT QA. Typical QA methods measure the dose in an array dosimeter surrounded by homogenous medium for which the treatment plan has been recomputed. With the Dosimetry Check system, fluence measurements acquired on a portal dosimeter is applied to the ...
Narayanasamy, Ganesh +4 more
openaire +2 more sources
Background Based on a previous study on the feasibility of TomoEQA, an exit detector-based patient-specific pre-treatment quality assurance (QA) method for helical tomotherapy, an in-depth clinical evaluation was conducted.
Changhwan Kim +5 more
doaj +1 more source
Background: Arc therapy allows for better dose deposition conformation, but the radiotherapy plans (RT plans) are more complex, requiring patient-specific pre-treatment quality assurance (QA). In turn, pre-treatment QA adds to the workload. The objective
Noémie Moreau +7 more
doaj +1 more source
Clinical performance of FractionLab in patient-specific quality assurance for intensity-modulated radiotherapy: a retrospective study [PDF]
Background This study was aimed at comparing and analyzing the results of FractionLab (Varian/Mobius Medical System) with those of portal dosimetry that uses an electronic portal imaging device.
Se An Oh +4 more
doaj +1 more source