Results 21 to 30 of about 85,674 (244)
Statistical Process Control in Monitoring Radiotherapy Quality Assurance Program: An Institutional Experience. [PDF]
Introduction: Statistical process control (SPC) is a handy and powerful tool for monitoring quality assurance (QA) programs in radiotherapy. This study explains the institutional experience in monitoring weekly output constancy QA and patient-specific ...
Vysakh R +3 more
doaj +1 more source
Survey of patient‐specific quality assurance practice for IMRT and VMAT [PDF]
AbstractA first‐time survey across 15 cancer centers in Ontario, Canada, on the current practice of patient‐specific quality assurance (PSQA) for intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) delivery was conducted.
Chan, Gordon H. +9 more
openaire +2 more sources
Introduction: Gated tangential field-in-field (FIF) technique is used to lower the dose to organs at risk for breast cancer radiotherapy (RT). In this study, the authors investigated the accuracy of the delivered treatment plan with and without gating ...
Dražan Jaroš +7 more
doaj +1 more source
Suitability Assessment of an Indigenous Heterogeneous Thoracic Phantom for Patient-Specific Quality Assurance in Radiotherapy [PDF]
Introduction: Patient-specific quality assurance (PSQA) assumes a vital role in precise and accurate radiation delivery to cancer patients. Since the patient body comprises heterogeneous media, the present study aimed to fabricate a heterogeneous ...
Vinod Gangwar +5 more
doaj +1 more source
Flexibility and efficiency in a radiotherapy department with different linear accelerators (linacs) can be improved if they are dosimetrically equivalent, and there is no need of plan or patient-specific quality assurance (PSQA) modification.
José Alejandro Rojas-López +1 more
doaj +1 more source
Feasibility of a 3D-printed anthropomorphic patient-specific head phantom for patient-specific quality assurance of intensity-modulated radiotherapy. [PDF]
This study evaluated the feasibility of utilizing a 3D-printed anthropomorphic patient-specific head phantom for patient-specific quality assurance (QA) in intensity-modulated radiotherapy (IMRT).
Ji Woon Yea +8 more
doaj +1 more source
A sophisticated machine of radiotherapy treatment process follows the complexity of the quality assurance (QA) measurement. Non-measurement QA becomes one of the solutions to reduce the medical physicists’ workload.
Akbar Azzi +2 more
doaj +1 more source
Patient specific quality assurance for the delivery of intensity modulated radiotherapy [PDF]
A patient specific quality assurance program has been developed to facilitate the clinical implementation of intensity modulated radiotherapy (IMRT) delivered using a micro‐multileaf collimator. The methodology includes several dosimetric tasks that are performed prior to the treatment of each patient.
Agazaryan, Nzhde +2 more
openaire +4 more sources
Comparing log file to measurement-based patient-specific quality assurance
Abstract Recent technological advances have allowed the possibility of performing patient-specific quality assurance (QA) without time-intensive measurements. The objectives of this study are to: 1) compare how well the log file-based Mobius QA system agrees with measurement-based QA methods (ArcCHECK and portal dosimetry, PD) in passing and ...
Li Ting Chan +9 more
openaire +2 more sources
VALIDATION OF COMPASS FOR PRE-TREATMENT PATIENT-SPECIFIC QUALITY ASSURANCE
Aim: Purpose of study is to validate COMPASS 3D patient specific quality-assurance software with Monaco treatment planning system (TPS) for routine quality assurance. Materials & methods: Purpose is to test the MLC modelling in COMPASS software, using Elekta Express QA package contains eight QA fields as follows (i) 10x10 (ii) 20x20 (iii) 3ABUT ...
Seema Sharma +8 more
openaire +2 more sources

