COMP Report: CPQR technical quality control guidelines for use of positron emission tomography/computed tomography in radiation treatment planning

open access: yesJournal of Applied Clinical Medical Physics, Volume 23, Issue 12, December 2022., 2022
Abstract Positron emission tomography with x‐ray computed tomography (PET/CT) is increasingly being utilized for radiation treatment planning (RTP). Accurate delivery of RT therefore depends on quality PET/CT data. This study covers quality control (QC) procedures required for PET/CT for diagnostic imaging and incremental QC required for RTP.
Ran Klein   +7 more
wiley   +1 more source

Joint application of hybrid iterative reconstruction and adaptive filters on neck‐and‐shoulder CT imaging: A clinical evaluation

open access: yesJournal of Applied Clinical Medical Physics, Volume 23, Issue 12, December 2022., 2022
Abstract Purpose To assess whether the joint application of hybrid iterative reconstruction (HIR) and an adaptive filter (AF) could reduce streak artifacts and improve image quality of neck‐and‐shoulder computed tomography (CT). Methods This study included 96 patients with suspicious neck lesions who underwent a routine nonenhanced scan on a 64‐slice ...
Wenfeng Jin   +6 more
wiley   +1 more source

Phenotypic continuum of NFU1‐related disorders

open access: yesAnnals of Clinical and Translational Neurology, Volume 9, Issue 12, Page 2025-2035, December 2022., 2022
Abstract Bi‐allelic variants in Iron–Sulfur Cluster Scaffold (NFU1) have previously been associated with multiple mitochondrial dysfunctions syndrome 1 (MMDS1) characterized by early‐onset rapidly fatal leukoencephalopathy. We report 19 affected individuals from 10 independent families with ultra‐rare bi‐allelic NFU1 missense variants associated with a
Rauan Kaiyrzhanov   +45 more
wiley   +1 more source

Does long‐term phenytoin have a place in Dravet syndrome?

open access: yesAnnals of Clinical and Translational Neurology, Volume 9, Issue 12, Page 2036-2040, December 2022., 2022
Abstract Anti‐seizure medications that block sodium channels are generally considered contraindicated in Dravet syndrome. There is, however, considerable debate about the sodium‐channel blocker phenytoin, which is often used for status epilepticus, a frequent feature of Dravet syndrome.
George A. Zographos   +2 more
wiley   +1 more source

Harmonizing results of ataxia rating scales: mFARS, SARA, and ICARS

open access: yesAnnals of Clinical and Translational Neurology, Volume 9, Issue 12, Page 2041-2046, December 2022., 2022
Abstract The ever‐increasing body of ataxia research provides opportunities for large‐scale meta‐analyses, systematic reviews, and data aggregation. Because multiple standardized scales are used to quantify ataxia severity, harmonization of these measures is necessary for quantitative data pooling. We applied the modified Friedreich Ataxia Rating Scale
Christian Rummey   +5 more
wiley   +1 more source

The clinical spectrum of SMA‐PME and in vitro normalization of its cellular ceramide profile

open access: yesAnnals of Clinical and Translational Neurology, Volume 9, Issue 12, Page 1941-1952, December 2022., 2022
Abstract Objective The objectives of this study were to define the clinical and biochemical spectrum of spinal muscular atrophy with progressive myoclonic epilepsy (SMA‐PME) and to determine if aberrant cellular ceramide accumulation could be normalized by enzyme replacement.
Michelle M. Lee   +16 more
wiley   +1 more source

Recognizing early MRI signs (or their absence) is crucial in diagnosing metachromatic leukodystrophy

open access: yesAnnals of Clinical and Translational Neurology, Volume 9, Issue 12, Page 1999-2009, December 2022., 2022
Abstract Objectives Metachromatic leukodystrophy (MLD) has characteristic white matter (WM) changes on brain MRI, which often trigger biochemical and genetic confirmation of the diagnosis. In early or pre‐symptomatic disease stages, these typical MRI changes might be absent, hampering early diagnosis.
Daphne H. Schoenmakers   +7 more
wiley   +1 more source

The Michigan Appropriateness Guide for Intravenous Catheters in Pediatrics: miniMAGIC.

open access: yesPediatrics, 2020
OBJECTIVES Vascular access device decision-making for pediatric patients remains a complex, highly variable process. To date, evidence-based criteria to inform these choices do not exist.
Amanda J. Ullman   +28 more
semanticscholar   +1 more source

Acute Lower Respiratory Infection Profile in Children at Tertiary Hospital Bandung: Is There a Difference Before and During COVID-19 Pandemic?

open access: yesGlobal Pediatric Health, 2022
This study aims to analyze differences of the prevalence and characteristics of acute lower respiratory infection (ALRI) in children at tertiary hospital before and during COVID-19 pandemic.
Allisa Majeda MD   +2 more
doaj   +1 more source

Perinatal-Neonatal Management of COVID-19 Infection — Guidelines of the Federation of Obstetric and Gynaecological Societies of India (FOGSI), National Neonatology Forum of India (NNF), and Indian Academy of Pediatrics (IAP)

open access: yesIndian Pediatrics, 2020
Justification During the current rapidly evolving pandemic of COVID-19 infection, pregnant women with suspected or confirmed COVID-19 and their newborn infants form a special vulnerable group that needs immediate attention.