Results 61 to 70 of about 128,782 (181)

Pullout Strength after Expandable Polymethylmethacrylate Transpedicular Screw Augmentation for Pedicle Screw Loosening

open access: yesJournal of Korean Neurosurgical Society, 2015
Pedicle screw fixation for spine arthrodesis is a useful procedure for the treatment of spinal disorders. However, instrument failure often occurs, and pedicle screw loosening is the initial step of a range of complications. The authors recently used a modified transpedicular polymethylmethacrylate (PMMA) screw augmentation technique to overcome ...
Kang, Suk-Hyung   +3 more
openaire   +2 more sources

Long‐term stability of horizontal bone augmentation at implant sites

open access: yesPeriodontology 2000, EarlyView.
Abstract Horizontal bone augmentation is a fundamental surgical procedure in regenerative implant dentistry. In recent decades, this procedure has evolved, enabling clinicians to achieve predictable and stable horizontal bone augmentation that supports dental implant restorations.
Jia‐Hui Fu   +3 more
wiley   +1 more source

Predictive Value of Preoperative Nutritional Risk Index for Screw Loosening After Lumbar Interbody Fusion in Elderly Patients With Lumbar Spine Diseases

open access: yesOrthopaedic Surgery
Objective Pedicle screw loosening is one of the common complications in elderly patients undergoing transforaminal lumbar interbody fusion (TLIF) for lumbar spine disease.
Youwei Ai   +11 more
doaj   +1 more source

An approximate model for cancellous bone screw fixation [PDF]

open access: yes, 2013
This is the author's accepted manuscript. The final published article is available from the link below. Copyright @ 2013 Taylor & Francis.This paper presents a finite element (FE) model to identify parameters that affect the performance of an improved ...
Brown, CJ   +9 more
core   +1 more source

Bone density optimized pedicle screw insertion [PDF]

open access: yes, 2023
Background: Spinal fusion is the most common surgical treatment for the management of degenerative spinal disease. However, complications such as screw loosening lead to painful pseudoarthrosis, and are a common reason for revision. Optimization of screw
Calek, Anna-Katharina; https://orcid.org/   +19 more
core   +1 more source

Novel dorsal occipito‐cervical fixation using a patient‐specific implant and drill guide for a complex craniocervical junction anomaly in a dog

open access: yesVeterinary Surgery, EarlyView.
Abstract Objective To describe a novel dorsal occipito‐cervical fixation technique utilizing a patient‐specific implant to stabilize complex craniocervical junction anomalies (CCJAs) in a small‐breed dog. Study design Case report. Animal A 7‐month‐old male Pomeranian dog.
Tae‐Wan Kwon   +4 more
wiley   +1 more source

Investigation on pullout strength between different design of cannulated pedicle screw and osteoporosis bones to obtain an optimum design [PDF]

open access: yes, 2019
Pedicle screws are widely used for the treatment of spinal instability by spine fusion. This treatment can be performed at any level in the spine (cervical, thoracic or lumbar) and prevents any movement between the fused vertebrae.
A., Asyraf   +3 more
core   +1 more source

Effect of Insertional Direction of Pedicle Screw on Screw Loosening: A Biomechanical Study on Synthetic Bone Vertebra under a Physiology‐like Load

open access: yesOrthopaedic Surgery
Objectives It is now understood that pedicle screw loosening at the implant‐bone interface can lead to poor screw–bone interface purchase and decreased fixation stability. Previous biomechanical tests used cadaveric vertebrae and pull‐out or torque loads
Xuqiang Zhan   +5 more
doaj   +1 more source

Augmented pedicle trajectory applied on the osteoporotic spine with lumbar degenerative disease: mid-term outcome

open access: yesJournal of Orthopaedic Surgery and Research, 2019
Purpose To compare the safety and efficiency of cement-augmented pedicle screw with traditional pedicle screw technique applied on the patients in the osteoporotic spine with lumbar degenerative diseases. Methods Fifty-six patients followed up at least 2
Guo-ye Mo   +9 more
doaj   +1 more source

Iliosacral Screw Fixation for Treating Sacral Fractures: A Modified Pedicle‐Guided Fixation Technique in Prone Position

open access: yesOrthopaedic Surgery, Volume 18, Issue 11, Page 2480-2490, November 2026.
Modified pedicle‐guided fixation technique for iliosacral screw placement in prone position reduces operation time and radiation exposure as conventional two‐dimensional fluoroscopy was enough to identify safe insertion corridors. Prone position is also advantageous when dealing with obese patients and concomitant spinal injuries.
Ben‐Mao Liu   +5 more
wiley   +1 more source

Home - About - Disclaimer - Privacy