Results 81 to 90 of about 4,335 (188)
This study compares the biomechanical effects of three anterior fixation systems in thoracolumbar surgery—HXTL, NHXTL, and Medtronic's CD Horizon ANTERIOR. Finite element analysis evaluates stress and displacement across vertebral bodies and support structures under varying load conditions. Results indicate the HXTL system minimizes nail–rod stress yet
Xuehai Jia +7 more
wiley +1 more source
Positioning of pedicle screws in adolescent idiopathic scoliosis using electromyography [PDF]
OBJECTIVE: To analyze the occurrence of poor positioning of pedicle screws inserted with the aid of intraoperative electromyographic stimulation in the treatment of Adolescent Idiopathic Scoliosis (AIS).METHODS: This is a prospective observational study ...
Bruno Moreira Gavassi +11 more
core +1 more source
The Role of Pedicle Screw Surface on Insertion Torque and Pullout Strength [PDF]
Objective Compare by mechanical tests the pullout resistance and the insertion torque of rough and smooth pedicle screws. Methods Pedicle screws with rough surface and smooth surface, with diameters of 4.8; 5.5 and 6.5 mm, were inserted in polyurethane ...
Rodrigo Barra Caiado Fleury +5 more
doaj +4 more sources
The research utilized a case–control approach to contrast patients experiencing unscheduled readmissions with those undergoing planned readmissions due to staged surgery. Findings indicated a 3.88% rate of unscheduled readmissions, mainly linked to adjacent segment disease, with 3.35% necessitating reoperation.
Wangmi Liu +5 more
wiley +1 more source
Schematic drawing showing the designation of synthetic vertebrae instrumented with various pedicle screws. [PDF]
Different-sized screws were chosen and randomly implanted into each pedicle of the vertebrae by an experienced surgeon, 6.0 mm × 45 mm, 6.0 mm × 50 mm, and 6.5 mm × 45 mm screws were inserted sequentially into the semi-pedicle (left side of A, B, C) and ...
Ming-Kai Hsieh (6894410) +6 more
core +1 more source
Background Intraoperative cone beam CT (CBCT) imaging in dorsal instrumentation facilitates pedicle screw positioning. However, in patients with obesity, the benefit may be reduced due to artifacts that affect image quality. The purpose of this study was
Felix Zimmermann +5 more
doaj +1 more source
Developed a staging system for adjacent segment disease based on degeneration characteristics. Verified the feasibility and reliability of stage‐guided surgical decision‐making through surgical data, radiological data, and follow‐up data. This staging system was closely correlated with intervertebral disc degeneration and disc height while also ...
Changpeng Qu +9 more
wiley +1 more source
Fenestrated Screws Augmented with PMMA Increase the Pull-out Strength of Sacral Pedicle Screws [PDF]
STUDY DESIGN:: Biomechanics. OBJECTIVE:: The objective of this study was to compare the fixation in osteoporotic specimens of a bicortical sacral pedicle screw to the following constructs: a unicortical solid screw augmented with PMMA (TRACT), a ...
Pond, Jonathan +11 more
core +1 more source
Endoscopic‐Assisted Posterior Atlantoaxial Fusion: Technical Innovation and Clinical Experience
Endoscopic‐assisted posterior atlantoaxial lateral mass fusion is introduced as a novel minimally invasive technique for treating atlantoaxial instability. The approach enables direct visualization, precise fixation, and effective bone fusion while minimizing muscle dissection, blood loss, and postoperative pain, achieving rapid neurological and ...
Jichong Zhu +7 more
wiley +1 more source
A new concept for implant fixation: bone-to-bone biologic fixation [PDF]
Many attempts have been made to reduce complications of bone implant, such as pedicle screw loosening. To address this problem, the authors suggest a new concept of bone-to-bone biologic fixation using recombinant human bone morphogenetic protein-2 ...
D-Y Kim, J-R Kim, KY Jang, K-B Lee
doaj