Results 1 to 10 of about 1,773 (146)

Electrode Degradation in PEMFCs as Studied in Model Systems and PEMFC Testing [PDF]

open access: yesECS Transactions, 2009
In order to meet the durability criteria for PEM Fuel Cells, needed for their successful application in transport, more insight is needed into which conditions have a detrimental effect on the long term performance, and which materials improvements are needed to make PEMFC better suited to withstand some of these conditions that are unavoidable in ...
Janssen, G.J.M.   +3 more
openaire   +3 more sources

Nonintrusive Diagnosis of a PEMFC [PDF]

open access: yesIEEE Transactions on Magnetics, 2015
Many reasons may cause malfunction of a proton exchange membrane fuel cell (FC) stack. Moreover, a single defect cell can affect the whole stack functioning; therefore, the localization of this cell is crucial as well as identifying the root causes for such malfunctioning.
Hinaje, Melika   +3 more
openaire   +4 more sources

Diagnostics Of Pemfc Degradation

open access: yesVehicle Power and Propulsion Conference 2017, 2017
The presentation illustrates the results of accelerated stress tests on the degradation of PEM fuel ...
Barbir, Frano   +6 more
openaire   +2 more sources

Real-Time Monitoring of HT-PEMFC [PDF]

open access: yesMembranes, 2022
During the electrochemical reaction of a high temperature proton exchange membrane fuel cell (HT-PEMFC), (in this paper HT-PEMFC means operating in the range of 120 to 200 °C) the inhomogeneity of temperature, flow rate, and pressure in the interior is likely to cause the reduction of ion conductivity or thermal stability weight loss of proton exchange
Chi-Yuan Lee   +4 more
openaire   +3 more sources

PEMFC Fault Diagnosis, Modeling, and Mitigation [PDF]

open access: yesIEEE Transactions on Industry Applications, 2008
This paper introduces fault diagnosis and separation, mitigation, and modeling of a proton exchange membrane fuel cell (PEMFC). Experimental tests of a single PEMFC were performed during this study. Flooding and drying faults were implemented to be detected from the cell voltage and impedance response of the cell.
Abraham Gebregergis   +2 more
openaire   +2 more sources

Simulation of PEMFC performance

open access: yesJournal of Renewable Energies, 2023
Throughout literature, there are two approaches to estimate fuel cells (FC) performance, by the evaluation of polarization curve. One includes, physical modelling of heat and mass transfer with electrochemical phenomena; the second is based on semiempirical equation used in order to analysis the effect of different physical perturbation on the ...
openaire   +2 more sources

Robust PID control of a PEMFC system

open access: yes2010 IEEE International Conference on Control Applications, 2010
This paper proposes robust proportional -integral-derivative (PID) control for a proton exchange membrane fuel cell (PEMFC) system. We model a PEMFC as a multivariable system, and apply identification techniques to obtain the system's transfer function matrices, where system variations and disturbances are regarded as system uncertainties.
Fu-Cheng Wang, Chin-Chun Ko
openaire   +1 more source

The Stability of PEMFC Electrodes [PDF]

open access: yesJournal of The Electrochemical Society, 2007
V. A. T. Dam, F. A. de Bruijn
openaire   +1 more source

Home - About - Disclaimer - Privacy