Results 81 to 90 of about 211,107 (233)
An original mininvasive corporoplasty technique for penile curvature without circumcision
Objective: We describe an original minimallyinvasive penile plication technique with scro-tal or infrapubic access, not requiring circumcision, for penilecurvature of different severity and types. This technique can beused to correct both congenital and
Pietro Viscuso +9 more
core
The SPG‐MpECis electrochemical POCT platform developed in this study enables direct detection of biomarkers in complex biological samples such as serum and fingerstick blood, demonstrating high concordance with results from clinical reference methods and holding broad potential for at‐home testing applications.
Menghan Li +10 more
wiley +1 more source
TP53 R249S mutation in hepatic organoids captures the predisposing cancer risk
The systematic approach in elucidating the gain‐of‐function (GOF) roles of TP53 mutations in early liver carcinogenesis. Unique downstream targets of TP53 L3 mutations were identified from chormatin immunoprecipitation sequencing in HCC cell lines, followed by a series of validation assays to substantiate the exclusive transcriptional regulations ...
Yin Kau Lam +10 more
wiley +1 more source
Peyronie’s disease (PD) is a condition of penile connective tissue affecting up to 10% of men worldwide. In the complexity of its management, nonsurgical treatments, such as intraplaque injections, are gaining attention. The current literature shows data
Simone Cilio +10 more
doaj +1 more source
Penile septoplasty for congenital ventral penile curvature: results in 51 patients
Purpose: The technique most widely used to correct congenital ventral penile curvature is still corporoplasty as originally described by Nesbit. We present results in patients treated with a variation of Nesbit corporoplasty used specifically for ...
G. Colpi +4 more
core +1 more source
Wetting‐Driven Transfer of Flexible Ultra‐Thin Temperature Sensors
A wetting‐driven transfer approach enables ultra‐thin temperature sensors to be transferred from a super‐hydrophilic donor substrate onto rigid, curved, and biological receiver substrates. By combining controlled wetting with a conformal Parylene carrier layer, the method preserves stable thermal sensing performance while expanding the integration of ...
Hafiza Faiqa Maqsood +5 more
wiley +1 more source
Performance and Environmental Impact of Flexible Temperature Sensors on Cellulose‐Based Substrate
Toward low‐environmental‐impact approach to thin‐film sensors fabrication using natural ingredient‐based triacetyl cellulose (TAC) substrate. Temperature sensors are fabricated and characterized based on thermal and mechanical performance. Substrate recovery is demonstrated by facile dissolution of a Mo‐based sensor in deionized water.
Dianne C. Corsino +14 more
wiley +1 more source
Free Charge Generation in Organic Photoconversion Devices–the Impact of Electrostatic Potentials
Free charge generation in organic photovoltaic and photodetector devices typically requires an external driving force to separate bound excitons formed upon photoexcitation. This review details how electrostatic potentials, arising from molecular charge distributions in organic semiconductors, can impact interfacial energetic landscapes and promote ...
Emily J. Yang +3 more
wiley +1 more source
Penile Plication With or Without Degloving of the Penis Results in Similar Outcomes
Background: Penile plication techniques with or without degloving offer a minimally invasive option for the treatment of penile curvature. Aim: To review the outcomes of penile plication surgery and patient satisfaction with and without degloving of the ...
Rustam Kadirov, MD +6 more
doaj +1 more source
Does the type of the Peyronie's curvature effect penile vascular parameters in normopotent men?
The aim of this study is to assess whether the type of penile curvature in normopotent men with Peyronie's disease affects the penil vascular doppler ultrasound parameters.
Metin, Ahmet +3 more
core +1 more source

