A Modified Arthroscopic Trans‐Septal Approach via the Figure‐to‐4 Position of the Knee
Abstract Standard anterior and posterior portals offer limited access to pathologies in the posterior compartment of the knee. The trans‐septal portal facilitates comprehensive visualization and instrumentation in the posterolateral and posteromedial compartments.
Ning Sheng +4 more
wiley +1 more source
Long-term success of percutaneously placed peritoneal dialysis catheters. [PDF]
Lorio A +5 more
europepmc +1 more source
All‐Inside, All‐Soft‐Tissue, Anchor‐Free Meniscal Allograft Transplantation
Abstract Meniscal allograft transplantation is an effective surgical option for patients with irreparable meniscal pathology, including chronic root tears, complex or radial tears, and prior meniscectomy. This Technical Note describes an all‐inside, all‐soft‐tissue, anchor‐free arthroscopic technique for meniscal allograft transplantation designed to ...
Seksan Kukreja +4 more
wiley +1 more source
Hepatic Compartment Syndrome Induced by Subcapsular Hematoma following Percutaneous Transhepatic Gallbladder Drainage: A Case Report. [PDF]
Miyazaki R +10 more
europepmc +1 more source
Abstract Successful medial collateral ligament (MCL) reconstruction depends on multiple anatomical and biomechanical factors. Various techniques have been described, ranging from isolated superficial MCL reconstructions to complex combined medial reconstructions.
Pablo Gelber +2 more
wiley +1 more source
Acute Hyponatremia as a Telling Complication of Necrotizing Pancreatitis and Perforated Cholecystitis After Percutaneous Cholecystostomy. [PDF]
Lee J, Kubey A.
europepmc +1 more source
Tensionable Knotless Tendon‐Sparing Biceps Rerouting Technique for Irreparable Rotator Cuff Tears
Abstract This technique describes a tensionable knotless tendon‐sparing biceps rerouting for superior capsular reconstruction using the long head of the biceps in irreparable supraspinatus tears. The long head of the biceps is arthroscopically released from the bicipital groove, rerouted over the greater tuberosity footprint, and secured with 2 self ...
Ignancio Pérez +5 more
wiley +1 more source
The Tendon‐to‐Bone Seam: A Transtendinous Approach to Rotator Cuff Repair
Abstract This technique article describes the tendon‐to‐bone seam technique, a knotless, transtendinous approach to arthroscopic rotator cuff repair. The technique employs a single‐use deployment device preloaded with multiple PEEK anchors interconnected with a single polyethylene #2 suture, enabling the surgeon to create a continuous “seam” of ...
James Tyler Frix +4 more
wiley +1 more source
Multiloculated Klebsiella liver abscess successfully treated with early laparoscopic drainage after failed percutaneous drainage: a case report. [PDF]
Nakahara S +4 more
europepmc +1 more source
Abstract Schatzker type III tibial plateau fractures, characterized by a pure depression of the lateral articular surface, predominantly affect osteoporotic, middle‐aged, and elderly patients. Successful management requires anatomical reduction and stable fixation to minimize complications like post‐traumatic arthritis.
Renbang Huang +3 more
wiley +1 more source

