Results 151 to 160 of about 32,051 (265)
Percutaneous Closure of a Left Ventricular Pseudoaneurysm
Julio Echarte-Morales +9 more
openaire +2 more sources
First tumor microenvironment (TME)‐responsive spermine‐loaded hydrogel with autonomous sensing for advanced local therapy of prostate cancer (PCa) is developed. Spermine can be released from the hydrogel to kill the prostate cancer cells specifically under acidic TME.
Ho‐Fai Chau +12 more
wiley +1 more source
Percutaneous Closure of Patent Foramen Ovale in a Patient With Incomplete Cor Triatriatum Sinister: A Case Report. [PDF]
Apostolos A +8 more
europepmc +1 more source
Percutaneous closure of patent foramen ovale
FX Kleber, A Stretz
openaire +3 more sources
Real‐world evidence (RWE) derived from real‐world data (RWD) can complement randomized controlled trials (RCTs), yet the validity of RWD relative to RCT data remains insufficiently characterized. We obtained post hoc consent and linked individual participant data from the US‐based INVESTED trial (2016–2019) with Medicare fee‐for‐service claims (2012 ...
Hanseul Cho +12 more
wiley +1 more source
Non-inferiority trial of remimazolam versus propofol for fast-track anesthesia in children undergoing percutaneous closure of atrial septal defect. [PDF]
Qin P +6 more
europepmc +1 more source
Betamethasone concentrations in 20 horses from Japan and Germany following IV, IM, and INJ administration of betamethasone phosphate were analyzed using population pharmacokinetic modeling. For IV administration of 0.04 mg/kg q24 h, IPC and IUC were 0.012 and 0.31 ng/mL, respectively; the IUC approximated the IFHA urine ISL (0.20 ng/mL).
Taisuke Kuroda +9 more
wiley +1 more source
Case Report: Percutaneous closure of patent ductus arteriosus with the KONAR-MF™ device: initial experience and results at 6 months in a tertiary center. [PDF]
Catalán Cabrera AI +4 more
europepmc +1 more source
Recent Advance for PVDF Based Flexible Piezoelectric Sensors
This review focus on the structural regulation of PVDF via boundary confinement, blending regulation, electric‐field‐assisted orientation, and chemical modification for flexible piezoelectric sensors. ABSTRACT The rapid advancement of flexible electronics, wearable devices, and biomedical engineering has spurred increasing demand for sensor materials ...
Chaoran Tan +4 more
wiley +1 more source
Long-term Echocardiographic Features After Percutaneous Closure of Patent Foramen Ovale. [PDF]
Rojko M +5 more
europepmc +1 more source

