Correlation between Periotest value and implant stability quotient: a systematic review
Biomedical Engineering / Biomedizinische Technik, 2023Abstract Objectives To determine, through clinical studies, whether there is a correlation between the Periotest value (PTV) and the implant stability quotient (ISQ). Content Methods to evaluate the stability of dental implants.
Alana Semenzin Rodrigues +4 more
openaire +2 more sources
COMPARISON OF PERIOTEST VALUES OF INTEGRATED IMPLANTS WITH AND WITHOUT HEALING ABUTMENTS
Implant Dentistry, 1996The role of the Periotest in the clinical evaluation of osseointegration has been well documented. Some clinicians have used the initial Periotest values at second-stage surgery as a baseline to measure changes in integration at the bone-implant interface over time.
H D, Barber +6 more
openaire +3 more sources
Periotest values of abutment teeth during prosthetic treatment with removable partial dentures
SUCHASNA STOMATOLOHIYA, 2023Actuality. Periotest (PT) is a diagnostic method, which allows for detection of the initial changes in the pathological mobility of teeth or dental prostheses. This method also allows for observation of the dynamics of changes in the periodontium after carrying out dental treatments.
A. Kovalyshyn, T. Dmytryshyn
openaire +1 more source
The Journal of Prosthetic Dentistry, 2020
Although the Periotest has been shown to provide reliable information about initial implant stability, whether Periotest values (PTVs) can be correlated with the stability of implants in function for several years is unclear.The purpose of this prospective clinical study was to investigate implant stability by using PTVs, as well as changes in ...
Waseem Khalaila +2 more
openaire +2 more sources
Although the Periotest has been shown to provide reliable information about initial implant stability, whether Periotest values (PTVs) can be correlated with the stability of implants in function for several years is unclear.The purpose of this prospective clinical study was to investigate implant stability by using PTVs, as well as changes in ...
Waseem Khalaila +2 more
openaire +2 more sources
The Influence of Bone Quality on Periotest Values of Endosseous Dental Implants at Stage II Surgery
Journal of Oral and Maxillofacial Surgery, 1997Periotest values (Periotest, Siemens AG, Bensheim, Germany) were recorded as a baseline variable at surgical uncovering in the ongoing multicenter, prospective clinical studies of the Dental Implant Clinical Research Group, which uses implants from the Spectra-System (Core-Vent Corporation, Las Vegas, NV).
R S, Truhlar +3 more
openaire +2 more sources
Use of 5‐mm‐diameter implants: Periotest® values related to a clinical and radiographic evaluation
Clinical Oral Implants Research, 1998A modified design of the original Brånemark implant consisting of a cp. Titanium 5.0‐mm‐diameter self‐tapping implant threaded up to the marginal platform has been proposed for specific indications. From February 1992 to November 1995, a total of 185 machined screw implants (Nobel Biocare, Gothenburg, Sweden) were installed in 45 patients to withstand ...
C, Aparicio, P, Orozco
openaire +2 more sources
American Journal of Orthodontics and Dentofacial Orthopedics, 2017
Approximately 14% of orthodontic anchor screws (miniscrews) become dislodged regardless of the accuracy of placement. It is therefore important to investigate the factors causing dislodgement. We evaluated the stability of miniscrews after placement to identify factors influencing outcome in orthodontic treatment using miniscrews.We investigated 120 ...
Takashi, Watanabe +5 more
openaire +2 more sources
Approximately 14% of orthodontic anchor screws (miniscrews) become dislodged regardless of the accuracy of placement. It is therefore important to investigate the factors causing dislodgement. We evaluated the stability of miniscrews after placement to identify factors influencing outcome in orthodontic treatment using miniscrews.We investigated 120 ...
Takashi, Watanabe +5 more
openaire +2 more sources
Influence of the implant abutment on the Periotest value: an in vivo study.
Quintessence international (Berlin, Germany : 1985), 2002Periotest values for dental implants depend on the type of prosthetic abutment utilized for the restoration. If Periotest value cannot be measured at the single crown, the Periotest values used for comparison must be derived from the same type of superstructure.Fifty-nine patients were selected from a regular follow-up program.
G, Gomez-Roman, D, Lukas
openaire +1 more source
The relationship of Periotest values, biomaterial, and torque to failure in adult baboons.
The International journal of prosthodontics, 1995A quantitative measure of implant stability would be beneficial to decision-making regarding the status of the bone anchorage around an implant. The Periotest device has been reported to provide such a measure, but the in vivo data are incomplete and inconclusive in support of this claim.
A B, Carr, E, Papazoglou, P E, Larsen
openaire +1 more source
[Influence of surface conditions on the results of Periotest value. An in vitro and in vivo study].
ZWR, 1992In several experiments it was examined, whether slight deviations from the using reglementation for the PERIOTEST-device alter the measurement results. Tilting of the handpiece against ground or variation of the distance between handpiece and the surface of the tooth within the suggested intervals did not alter the PERIOTEST-value.
H, Jakstat, T, Offenbächer, A, Genieser
openaire +1 more source