Purpose: The purpose of this study was to compare calibration factors for deep dose equivalent Hp (10) and shallow dose equivalent Hp (0.07) between Cesium (Cs)-137 and X-ray sources when they are exposed to same dose and to determine uncertainties with ...
Akintayo Daniel Omojola +3 more
doaj +1 more source
Managing toxicities associated with immune checkpoint inhibitors: consensus recommendations from the Society for Immunotherapy of Cancer (SITC) Toxicity Management Working Group. [PDF]
Cancer immunotherapy has transformed the treatment of cancer. However, increasing use of immune-based therapies, including the widely used class of agents known as immune checkpoint inhibitors, has exposed a discrete group of immune-related adverse ...
Abdallah, K. +80 more
core +2 more sources
Switching patients from other inhaled corticosteroid devices to the Easyhaler(®) : historical, matched-cohort study of real-life asthma patients [PDF]
Peer reviewedPublisher ...
Gould, Shuna +5 more
core +1 more source
International Comparison Results of Personal Dose Equivalent Hp(0.07) and Hp(3) in Beta Radiation
To establish the national primary standard for beta radiation tissue absorbed dose and to achieve international equivalence, the National Institute of Metrology (NIM) of China participated in the BIPM KCDB: EURAMET.RI(I)-S16 comparison that organized by ...
ZHANG Xuan1, 2, HUANG Jianwei1, LI Dehong1, , LIU Chuanfeng1, ZHANG Jian1, YANG Zhijun1, YANG Yang1
doaj +1 more source
Evaluation of Natural Radionuclide content in Nile River Sediments and Excess Lifetime Cancer Risk Associated with Gamma Radiation [PDF]
Introduction: This Study has was carried out to measure and detect the natural occurred radionuclide content including 226Ra, 232Th and 40K in the Nile River sediments at various locations in Upper Egypt, from Aswan to El-Minya.
Atef ElTaher +3 more
doaj +1 more source
Introduction: Some concepts of radiation protection are not well understood and must be refreshed periodically. The basic knowledge that a vascular surgeon must have about radiation protection for patients and staff is summarised.
Rodrigo Rial, Eliseo Vañó
doaj +1 more source
Individual monitoring at accelerator centres [PDF]
The accurate determination of personal dose equivalent requires the proper use of appropriate radiological quantities and units, knowledge of the dose equivalent response of the personal dosemeters used and detailed information on the fluence as well as ...
Wernli, Christian
core
Measurements of eye lens doses in interventional cardiology using OSL and electronic dosemeters [PDF]
The purpose of this paper is to test the appropriateness of OSL and electronic dosemeters to estimate eye lens doses at interventional cardiology environment.
Duch Guillen, María Amor +4 more
core +2 more sources
Importance of personal dose equivalent evaluation in Fukushima in overcoming social panic
The relationship between the reported ambient dose equivalent (H*(10)) and the individual dose rate recorded by medical staff in Fukushima City after the accident at the Fukushima Daiichi nuclear power plant was evaluated, following a 9.0-magnitude earthquake that struck the east coast of Japan. Personal dose equivalent (H(p)(10)) ranged from 0.08 to 1.
Kohji, Yoshida +5 more
openaire +2 more sources
Study of whole-body occupational radiation exposure in the industrial radiography in Bangladesh
Objective: In order to understand the complete scenario of the effectiveness of radiation protection practice in the workplace, especially in the industrial radiography and also to analyze the trends with other related studies, epidemiological studies ...
Selina Yeasmin +5 more
doaj +1 more source

