Results 21 to 30 of about 14,378 (188)
Design Optimization of PMU Anti-Aliasing Filters using Taguchi Method
A Phasor Measurement Unit (PMU) is a monitoring device, which serves in checking the power system condition by measuring voltage and current phasors along with frequency at a particular node.
Fatma Zohra DEKHANDJI
doaj +1 more source
Penempatan Phasor Measurement Unit untuk Menentukan Prediksi Margin Kestabilan Tegangan
The development of power system in new transmission and generation facilities has burdened the power system more than before. As a consequence, many power systems are facing voltage problems which will lead to voltage instability.
Levin Halim +2 more
doaj +1 more source
One challenge in Wide Area Measurement System is to design a reliable network which assures data availability. The availability of data in Phasor Measurement Unit (PMU) networks depends on two factors: 1‐Reliable data measurements which depend on ...
Maryam Dehghani, Navid Vafamand
doaj +1 more source
This paper discusses the details of the development of a Phasor Measurement Unit regarding the requirements of the IEEE C37.118-2005 synchrophasor standard relative to steady-state conditions on grid monitoring and control.
Ndilimabaka Hervé, Blanc Isabelle
doaj +1 more source
Efficient detection for multifrequency dynamic phasor analysis [PDF]
Analysis of harmonic and interharmonic phasors is a promising smart grid measurement and diagnostic tool. This creates the need to deal with multiple phasor components having different amplitudes, including interharmonics with unknown frequency locations.
Frigo, Guglielmo +2 more
core +1 more source
BabelFish—Tools for IEEE C37.118.2-compliant real-time synchrophasor data mediation
BabelFish (BF) is a real-time data mediator for development and fast prototyping of synchrophasor applications. BF is compliant with the synchrophasor data transmission IEEE Std C37.118.2-2011.
M.S. Almas, L. Vanfretti, M. Baudette
doaj +1 more source
Phasor Measurement Unit Incorporated Adaptive Out-of-step Protection of Synchronous Generator
The existing out-of-step (OOS) protection schemes have proven to be deficient in the prevention of significant outages. OOS protection schemes must not operate in stable power swing, and rapidly isolate an asynchronous generator or group of generators ...
Jigneshkumar P. Desai, Vijay H. Makwana
doaj +1 more source
P-class phasor measurement unit algorithms using adaptive filtering to enhance accuracy at off-nominal frequencies [PDF]
While the present standard C.37.118-2005 for Phasor Measurement Units (PMUs) requires testing only at steady-state conditions, proposed new versions of the standard require much more stringent testing, involving frequency ramps and off-nominal frequency ...
Abdulhadi, I. F +2 more
core +2 more sources
[Introduction] With the access of large-scale distributed generation and flexible load in distribution network, the accuracy and speed of traditional terminal measurement are difficult to meet the actual needs, while the new generation of distribution ...
XIONG Wen +5 more
doaj +1 more source
Globally optimal phasor measurement unit placement using branch and bound algorithm
This paper presents a new global optimal Phasor Measurement Unit (PMU) placement approach based on branch and bound algorithm. The proposed technique provides the global minimum number and locations of PMUs for any power system.
Mohamed Z. Kamh +2 more
doaj +1 more source