Results 81 to 90 of about 172,451 (245)

The effect of multi‐leaf collimator leaf width on VMAT treatment plan quality

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background The advent of volumetric modulated arc therapy (VMAT) in radiotherapy has made it one of the most commonly used techniques in clinical practice. VMAT is the delivery of intensity modulated radiation therapy (IMRT) while the gantry is in motion, and existing literature has shown it has decreased treatment delivery times and the ...
Gregory Sadharanu Peiris   +3 more
wiley   +1 more source

Evaluation of the dose reduction effect of crystalline lens exposure in cone‐beam computed tomography with bismuth eye shield for image‐guided radiation therapy: An anthropomorphic phantom study

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract This study aimed to evaluate the dose‐exposure reduction effect of a crystalline lens with a bismuth eye shield using cone‐beam computed tomography (CBCT) for head image‐guided radiation therapy. The ocular surface dose of the head phantom (THRA‐1) is defined as a crystalline lens exposure dose and is measured using a radiophotoluminescence ...
Tatsuya Yoshida   +5 more
wiley   +1 more source

The Selection of Photons Orbital Angular Momentum Generation Method for FSO

open access: yesEPJ Web of Conferences, 2015
The paper deals with methods of the realization of the various states of the orbital angular momentum (OAM) of photons. In a method of phase correction (MPC) a stream of photons with a certain mode of orbital angular momentum is used, in the reception ...
Kuzyakov B.A.   +2 more
doaj   +1 more source

Photon-Photon and Electron-Photon Physics or Physics at Photon Collider

open access: yes, 2003
14 pages, 18 figures, styles included; presented at Internatonal Workshop on Linear Colliders (LCWS2002), Jeju Island, Korea, 26-30 August ...
openaire   +2 more sources

Measuring photon-photon interactions via photon detection [PDF]

open access: yesPhysical Review A, 2010
The strong non-linearity plays a significant role in physics, particularly, in designing novel quantum sources of light and matter as well as in quantum chemistry or quantum biology. In simple systems, the photon-photon interaction can be determined analytically. However, it becomes challenging to obtain it for more compex systems.
openaire   +4 more sources

From 2D to 3D gamma passing rate tolerance and action limits for patient‐specific quality assurance in volumetric‐modulated arc therapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background Volumetric modulated arc therapy (VMAT) requires an accurate patient‐specific quality assurance (PSQA) program. In clinical practice, this is usually performed using the γ‐index and the two‐dimensional gamma passing rate (2D %GP). A three‐dimensional (3D) index incorporating the patient anatomy could be more useful for the 3D dose ...
Christos Zarros   +6 more
wiley   +1 more source

Does dose calculation algorithm affect the dosimetric accuracy of synthetic CT for MR‐only radiotherapy planning in brain tumors?

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study compares the dosimetric accuracy of deep‐learning‐based MR synthetic CT (sCT) in brain radiotherapy between the Analytical Anisotropic Algorithm (AAA) and AcurosXB (AXB). Additionally, it proposes a novel metric to predict the dosimetric accuracy of sCT for individual post‐surgical brain cases.
Jeffrey C. F. Lui   +3 more
wiley   +1 more source

Modelling of a double‐scattering proton therapy nozzle using the FLUKA Monte Carlo code and analysis of linear energy transfer in patients treated for prostate cancer

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background The dose‐averaged linear energy transfer (LETD) in proton therapy (PT) has in pre‐clinical studies been linked to the relative biological effectiveness (RBE) of protons. Until recently, the most common PT delivery method in prostate cancer has been double‐scattered PT, with LETD only available through dedicated Monte Carlo (MC ...
Rasmus Klitgaard   +7 more
wiley   +1 more source

Impact of enhanced leaf model on dose calculation accuracy in single‐isocenter multitarget stereotactic radiosurgery treatments

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Single‐isocenter multitarget (SIMT) radiosurgery has become increasingly popular as advancement in planning and delivery systems have made this approach clinically viable. With targets varying in size and distance from isocenter, SIMT plans are highly complex with dynamic multileaf collimator (MLC) motion.
Hem Moktan   +3 more
wiley   +1 more source

JACMP 2015 – 2019

open access: yes
Journal of Applied Clinical Medical Physics, EarlyView.
Per. H. Halvorsen
wiley   +1 more source

Home - About - Disclaimer - Privacy