Results 161 to 170 of about 568,064 (303)

Obese patient imaging: Potential dose reduction with photon-counting CT. [PDF]

open access: yesJ Appl Clin Med Phys
Liu LP   +10 more
europepmc   +1 more source

Force–Displacement Characterization of PNIPAM Microactuators

open access: yesAdvanced Robotics Research, EarlyView.
A method to experimentally establish a force–displacement diagram of poly(N‐isopropyl acrylamide) (PNIPAM) microactuators, printed by 2PP, is presented herein. PNIPAM is a hydrogel whose volume and stiffness change with temperature due to the absorption or release of water.
Manon Cassignol   +4 more
wiley   +1 more source

X-ray detector system based on photon counting

open access: yes, 2018
Disclosed is an x-ray detector system including a multitude of detector elements, each connected to a respective photon counting channel for providing at least one photon count output, and a read-out unit connected to the photon counting channels for ...
Svensson, Christer,   +3 more
core  

PHOTON-COUNTING CT & ADVANCED CT TECHNOLOGIES

open access: yes
Computed Tomography (CT) has undergone remarkable technological evolution since its clinical introduction in the 1970s. The advent of Photon-Counting Computed Tomography (PCCT) represents a fundamental paradigm shift in X-ray detection and image ...
Vikas Kumar   +3 more
core   +1 more source

Robotics in Ionizing Radiation Environments: Vulnerabilities, Hardening, and Future Directions

open access: yesAdvanced Robotics Research, EarlyView.
Radiation exposure causes cumulative degradation in robotic sensors, actuators, and electronic logic, often leading to undetected failures. This study maps component vulnerabilities, evaluates hardening and shielding strategies, and identifies testing gaps that must be addressed to enable next‐generation radiation‐tolerant robotic systems.
Francis A. K. Djirackor   +4 more
wiley   +1 more source

Microscale Mapping of Fiber Strain and Damage in Composite Wrinkled Laminates Using Computed Tomography Assisted Wide‐Angle X‐Ray Scattering

open access: yesAdvanced Science, EarlyView.
This study combines full‐field tomography with diffraction mapping to quantify radial (ε002$\varepsilon _{002}$) and axial (ε100$\varepsilon _{100}$) lattice strain in wrinkled carbon‐fiber specimens for the first time. Radial microstrain gradients (−14.5 µεMPa$\varepsilon \mathrm{MPa}$−1) are found to signal damage‐prone zones ahead of failure, which ...
Hoang Minh Luong   +7 more
wiley   +1 more source

Mitochondria and Neuromast Tagging With Fluorescent Gallium‐Triapine Analogues: In Cellulo MP FLIM and Zebrafish Live Imaging

open access: yesAdvanced Science, EarlyView.
Fluorescent BODIPY‐conjugated thiosemicarbazone ligands and their Ga(III), In(III), and Fe(III) complexes, inspired by Triapine, are developed as theranostic agents. Multiphoton FLIM and confocal microscopy in cancer cells and zebrafish reveal real‐time uptake, mitochondrial localisation, and whilst spectroscopic assays indicated preserved complex ...
Megan J. Green   +15 more
wiley   +1 more source

Home - About - Disclaimer - Privacy