Results 61 to 70 of about 5,909,316 (185)

Detection voltage PSD (distance PSD-VCSEL 20 cm) without collimation

open access: yes, 2022
The dataset contains the voltage measured  by a PSD (Position Sensing Detector) depending on the x-position of a  VCSEL light source (850 nm). The VCSEL is not collimated, and at a z-position of 20 cm of the PSD.
Robert (12632236)
core   +1 more source

Impact of P2O5 concentration on gamma-ray shielding in Na2O–B2O3-P2O5 glass

open access: yesNuclear Analysis
Building on our previous study of structural, and electrical properties of Na2O–B2O3–P2O5 work investigates their γ-ray shielding performance. Glasses with compositions 30Na2O – (70-y) B2O3–y P2O5 (where y = 0, 14, 21, and 35 mol%) were analyzed using ...
Issam Idrissi Janati   +3 more
doaj   +1 more source

Computation of Neutron Coefficients for B2O3 reinforced Composite [PDF]

open access: yes, 2023
Radiation is an important phenome and is used in different area since its discovery. Although there are different types of radiation, neutron is one of the most interesting types as it is an uncharged particle.
Oruncak, Bekir, Bekir ORUNCAK
core   +1 more source

Theoretical Calculation of Radiation Shielding Properties of B2O3–Bi2O3–Al2O3–MgO Glasses Alloyed with MnO

open access: yesمجلة بغداد للعلوم
The current work aims to calculate the gamma-ray shielding coefficients for six samples. The samples were 65B2O3.20Bi2O3.10Al2O3. (5-x) MgO. xMnO (0 ≤ x ≤ 1 mol%). prepared these samples by using the melt quenching method.
Shlair Ibrahim Mohammed   +1 more
doaj   +1 more source

In‐house development of CT‐based 3D‐printed head & neck phantom for Radiotherapy applications

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 7, July 2026.
Abstract Background Anthropomorphic phantoms are widely used in Radiotherapy for quality assurance (QA), treatment verification and dosimetric validation purposes. However, commercially available anthropomorphic phantoms are expensive and offers limited customization, restricting their broader clinical use.
Subhalaxmi Mishra   +6 more
wiley   +1 more source

Detection voltage PSD (distance PSD-VCSEL 8.5 cm) without collimation

open access: yes, 2022
  The dataset contains the voltage measured  by a PSD (Position Sensing Detector) depending on the x-position of a  VCSEL light source (850 nm). The VCSEL is not collimated, and at a z-position of 8.5 cm of the PSD.
Robert (12632236)
core   +1 more source

Effect of Increasing Weight of SiC Ceramic on Radiation Shielding of Al 2219

open access: yesGazi Üniversitesi Fen Bilimleri Dergisi
Artificial radiation has many disadvantages as well as benefits. In order to eliminate or minimize these disadvantages and to be an alternative to radiation shield materials used, Al 2219 alloy material, Al 2219+% 5 SiC, Al 2219+% 10 SiC, Al 2219+% 15 ...
Kubilay Akgül   +4 more
doaj   +1 more source

Mechanical properties as well as gamma-ray attenuation competence: a wide-ranging examination into Tb3+ doped boro-germanate-aluminiophosphate (BGAP) glasses

open access: yesJournal of Materials Research and Technology, 2022
The mechanical properties and radiation attenuation competence of Tb3+ ions doped boro-germanate-aluminiophosphate (BGAP) glasses with codes Tb15, Tb20, Tb25, Tb30, Tb35, and Tb40 have been investigated.
Hesham M.H. Zakaly   +6 more
doaj   +1 more source

Fabrication of High‐Density Multimodal Neural Probes Based on Heterogeneously Integrated CMOS

open access: yesAdvanced Science, Volume 13, Issue 34, 19 June 2026.
A chiplet‐based methodology democratizes active neural probe development on standard bulk CMOS services. This yields the first probe combining high‐density electrophysiology (416 electrodes) with calcium imaging (832 photodiodes) and complete on‐chip signal processing across 13 shanks.
Ju Hee Mun   +10 more
wiley   +1 more source

Detection voltage PSD (distance PSD-VCSEL 20 cm) with collimation

open access: yes, 2022
The dataset contains the voltage measured  by a PSD (Position Sensing Detector) depending on the x-position of a  VCSEL light source (850 nm). The VCSEL is collimated, and at a z-position of 20 cm of the PSD.
Robert (12632236)
core   +1 more source

Home - About - Disclaimer - Privacy