Results 231 to 240 of about 5,629,721 (306)

Feasibility study of skin dosimetry with TLD sheets for measuring the effect of 3D printed bolus in radiotherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract The thermoluminescence dosimeter (TLD) sheet is a measurement device coated with manganese‐doped LiB3O5 in sheet form. The sheet is 0.2‐mm thick and flexible. Hence, it can fit and be installed on irregular surfaces. The current study aimed to evaluate the feasibility of measuring patient surface doses during radiation therapy using TLD sheets.
Yuya Miyasaka   +8 more
wiley   +1 more source

Automatic skin flash optimization in breast and chestwall VMAT with static angle modulated ports: Effect of HU and flash margin size on plan quality and robustness

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Skin flash is typically added to breast and chestwall plans to ensure robust target coverage in the presence of respiratory motion, anatomic changes, and small setup uncertainties. Adding skin flash in volumetric modulated arc therapy (VMAT) plans is an iterative and manual process.
Emily Hubley   +6 more
wiley   +1 more source

Biophysical and biochemical aspects of immune cell-tumor microenvironment interactions. [PDF]

open access: yesAPL Bioeng
Benmelech S   +7 more
europepmc   +1 more source

Applied Physical Sciences in the University of Reading: Prof. P. B. Fellgett [PDF]

open access: bronze, 1965
Farquharson Is Brown   +5 more
openalex   +1 more source

Assessing HyperSight iterative CBCT for dose calculation in online adaptive radiotherapy for pelvis and breast patients compared to synthetic CT

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose/objectives Recent technological advancements have increased efficiency for clinical deliverability of online‐adaptive‐radiotherapy (oART). Previous cone‐beam‐computed‐tomography (CBCT) generations lacked the ability to provide reliable Hounsfield‐units (HU), thus requiring oART workflows to rely on synthetic‐CT (sCT) images derived ...
Jingwei Duan   +7 more
wiley   +1 more source

Impact of enhanced leaf model on dose calculation accuracy in single‐isocenter multitarget stereotactic radiosurgery treatments

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Single‐isocenter multitarget (SIMT) radiosurgery has become increasingly popular as advancement in planning and delivery systems have made this approach clinically viable. With targets varying in size and distance from isocenter, SIMT plans are highly complex with dynamic multileaf collimator (MLC) motion.
Hem Moktan   +3 more
wiley   +1 more source