Assessing HyperSight iterative CBCT for dose calculation in online adaptive radiotherapy for pelvis and breast patients compared to synthetic CT

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose/objectives Recent technological advancements have increased efficiency for clinical deliverability of online‐adaptive‐radiotherapy (oART). Previous cone‐beam‐computed‐tomography (CBCT) generations lacked the ability to provide reliable Hounsfield‐units (HU), thus requiring oART workflows to rely on synthetic‐CT (sCT) images derived ...
Jingwei Duan   +7 more
wiley   +1 more source

Evaluating the use of diagnostic CT with flattening filter free beams for palliative radiotherapy: Dosimetric impact of scanner calibration variability

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Palliative radiotherapy comprises a significant portion of the radiation treatment workload. Volumetric‐modulated arc therapy (VMAT) improves dose conformity and, in conjunction with flattening filter free (FFF) delivery, can decrease treatment times, both of which are desirable in a population with a high probability of retreatment ...
Madeleine L. Van de Kleut   +2 more
wiley   +1 more source

Improving organ dose sparing in left‐sided breast cancer with yaw‐limited volumetric modulated arc therapy: A dosimetric comparison to conventional and intensity modulated radiation therapy approaches

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background To assess the dose‐sparing capabilities of a yaw‐limited volumetric modulated arc therapy (YL_VMAT) beam setup for adjacent organs at risk (OAR) in comparison with 3D‐conventional radiation therapy (3D‐CRT), intensity‐modulated radiation therapy (IMRT) and conventional VMAT for radiation therapy in left‐sided breast cancer patients.
Gerhard Pollul   +4 more
wiley   +1 more source

Evaluation of the effect of metal stents on dose perturbation in the carbon beam irradiation field

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Propose Carbon ion therapy is indicated for cases in which stents have been inserted, such as bile ducts, but the effect of metal stents on carbon ion therapy is unclear. In this study, the dose perturbation of carbon ion therapy caused by metallic bile duct stents was evaluated by dosimetry. Materials and methods Five different types of metal
Yuya Miyasaka   +8 more
wiley   +1 more source