Abstract Purpose The dual‐layer multileaf collimator (MLC) in Halcyon adds complexities to the dose calculation process owing to the variability of dosimetric characteristics with leaf motion. Recently, an enhanced leaf model (ELM) was developed to refine the MLC model in the Eclipse treatment planning system. This study investigates the performance of
Ryohei Miyasaka+6 more
wiley +1 more source
Closing the gap in plan quality: Leveraging deep‐learning dose prediction for adaptive radiotherapy
Abstract Purpose Balancing quality and efficiency has been a challenge for online adaptive therapy. Most systems start the online re‐optimization with the original planning goals. While some systems allow planners to modify the planning goals, achieving a high‐quality plan within time constraints remains a common barrier.
Sean J. Domal+9 more
wiley +1 more source
Abstract Purpose Studies on deep learning dose prediction increasingly focus on 3D models with multiple input channels and data augmentation, which increases the training time and thus also the environmental burden and hampers the ease of re‐training. Here we compare 2D and 3D U‐Net models with clinical accepted plans to evaluate the appropriateness of
Rosalie Klarenberg+2 more
wiley +1 more source
Spin Seebeck in the weakly exchange-coupled Van der Waals antiferromagnet across the spin-flip transition. [PDF]
He X+13 more
europepmc +1 more source
Atomic processes in basic and applied physics
V. Shevelko, H. Tawara
semanticscholar +1 more source
Commissioning evaluation of a deviceless 4DCT scanner
Abstract Background The utilization of four‐dimensional computed tomography (4DCT) for radiation therapy has not seen major advances to the method of data binning since shortly after inception. Recently there is increased interest in the utilization of an alternative binning method rather than more established techniques.
Hunter Tillery+2 more
wiley +1 more source
Retraction notice to "Examinations of mechanical, and shielding properties of CeO<sub>2</sub> reinforced B<sub>2</sub>O<sub>3</sub>-ZnF<sub>2</sub>-Er<sub>2</sub>O<sub>3</sub>-ZnO glasses for gamma-ray shield and neutron applications" [Heliyon 9 (2023) e14435]. [PDF]
Alyousef HA+7 more
europepmc +1 more source
Abstract Background Acceleration treatment (AT) is a novel treatment planning parameter introduced in the tomotherapy‐dedicated treatment planning system, Precision. This study explores the effects of AT on tomotherapy plans using helical (TomoHelical) and direct (TomoDirect) irradiation techniques.
Ryosuke Shirata+9 more
wiley +1 more source
Correction: Robust low threshold full-color upconversion lasing in rare-earth activated nanocrystal-in-glass microcavity. [PDF]
Gao Z+9 more
europepmc +1 more source
Dose rate correction of a diode array for universal wedge field dosimetric verification
Abstract Purpose To study the performance of MapCHECK 3 (MC3) in measuring universal wedge fields and propose a dose rate correction strategy to improve MC3 measurement accuracy. Materials and methods Universal wedge fields with different wedge angles and field sizes were measured at different depths using MC3.
Linyi Shen+6 more
wiley +1 more source