Results 11 to 20 of about 45,635 (265)
Flow pumping system for physiological waveforms [PDF]
A pulsatile flow pumping system is developed to replicate flow waveforms with reasonable accuracy for experiments simulating physiological blood flows at numerous points in the body. The system divides the task of flow waveform generation between two pumps: a gear pump generates the mean component and a piston pump generates the oscillatory component ...
Tsai, William, Savaş, Ömer
openaire +4 more sources
Patients with neuromuscular disease often suffer from weak and ineffective cough resulting in mucus retention and increased risk for chest infections. Different airway clearance techniques have been proposed, one of them being the insufflator/exsufflator
Carmen Casaulta +4 more
doaj +1 more source
Heat and moisture exchange filters create additional dead space, comparable in volume to physiological, in premature newborns. It makes carbon dioxide remove difficultу.
A. N. Shmakov +3 more
doaj +1 more source
Newtonian and Non-Newtonian Pulsatile Flows through an Artery with Stenosis
The current study presents three-dimensional modeling and analysis of blood flow through artery stenosis under several variants of pulsatile flow to mimic the atherosclerosis artery disease.
Abdus Samad +3 more
doaj +1 more source
Respiratory maneuvers in echocardiography: a review of clinical applications
During echocardiographic examination, respiration induces cyclic physiological changes of intracardiac haemodynamics, causing normal variations of the right and left ventricle Doppler inflows and outflows and physiological variation of extracardiac flows.
Beladan Carmen C +4 more
doaj +1 more source
Annexins are a multifunctional class of calcium-binding proteins in plants, and their physiological functions and regulation in response to drought stress remain to be elucidated. Here, we found that AtANN2 and AtANN3 conferred to drought tolerance under
Ting Liu +9 more
doaj +1 more source
A novel roller pump for physiological flow [PDF]
AbstractHaving physiological correct flow waveforms is a key feature for experimental studies of blood flow, especially in the process of developing and testing a new medical device such as stent, mechanical heart valve, or any implantable medical device that involves circulation of blood through the device.
Albert Chong +6 more
openaire +3 more sources
Understanding physiological and degenerative natural vision mechanisms to define contrast and contour operators. [PDF]
BACKGROUND:Dynamical systems like neural networks based on lateral inhibition have a large field of applications in image processing, robotics and morphogenesis modeling.
Jacques Demongeot +3 more
doaj +1 more source
Inlet and outlet boundary conditions (BCs) play an important role in newly emerged image-based computational hemodynamics for blood flows in human arteries anatomically extracted from medical images.
Huidan Yu +8 more
doaj +1 more source
Characteristics of Blood Vessel Wall Deformation with Porous Wall Conditions in an Aortic Arch
Blood vessels have been modeled as non-porous structures that are permeable to solutes mixed in the blood. However, the use of non-physiological boundary conditions in numerical simulations that assume atmospheric pressure at the outlet does not ...
Cheema Taqi Ahmad +5 more
doaj +1 more source

