Results 81 to 90 of about 3,654,033 (309)
His bundle pacing – a new word in technology of pacing and treatment of heart failure [PDF]
The article presents review of the literature, clinical studies and current guidelines for the usage of His bundle pacing – a new method of treatment of bradycardia and heart blockades. Despite certain temporary limitations – lack of results of the large
Ya.V. Skybchyk +4 more
core +2 more sources
Interesting electrophysiological phenomenon during positioning of the lead deep inside the septum
Left bundle branch pacing (LBBP) is a developing physiological pacing technique. Wu et al. proposed that direct LBB capture could be confirmed by recording retrograde His potential (PoReHis) and mapping of the left conduction system potential.
Jiabo Shen +3 more
doaj +1 more source
NeuroVisio SyncPatch integrates skin‐conformal electromyography (EMG) electrodes with camera‐tracked markers to jointly assess muscle activity and three‐dimensional knee kinematics during rehabilitation. Parallel feedback pathways provide real‐time kinematic guidance during movement and post‐trial neuromuscular feedback.
Bohyung Choi +11 more
wiley +1 more source
Background: Physiological pacing has gained significant interest due to its potential to achieve optimal hemodynamic response. This study aimed to assess left ventricular performance in terms of electrical parameters, specifically QRS duration and ...
Giorgia Azzolini +6 more
doaj +1 more source
Soft and Transient Bioelectronics Enabled by Polymer‐Free Ti3C2Tx MXene Hydrogels
We present Ti3C2Tx MXene hydrogel (MXgel) bioelectronics, a soft, flexible, and fully transient platform for high‐fidelity neural recording and stimulation. MXgel bioelectronics exhibit exceptional electrical conductivities, low electrochemical impedances, and high charge injection capacities.
Raghav Garg +15 more
wiley +1 more source
How to achieve balloon stability in aortic valvuloplasty using rapid ventricular pacing [PDF]
Balloon aortic valvuloplasty is now the treatment of choice for congenital aortic stenosis. Balloon stability may be difficult to achieve and this may result in a suboptimal result or even valve damage.
Shebani, S. +3 more
core
Patient‐activated anti‐tachycardia pacing in adult congenital heart disease
INTRODUCTION: In adults with congenital heart disease, intra‐atrial reentrant tachycardia (IART) is a common arrhythmia that causes significant morbidity and mortality. One treatment option for IART is antitachycardia pacing.
Ahmad Sami Chaouki +8 more
core +1 more source
His bundle pacing is a direct pacing of the specialized His-Purkinje conduction system with the aim of physiological ventricular activation, in contrast to the dyssynchronous activation by conventional myocardial pacing.In this review article on His ...
S. N. Krivolapov +4 more
doaj +1 more source
Atrial-His bundle pacing in fulminant myocarditis with ventricular arrhythmia: a case report
Background Fulminant myocarditis is a clinical syndrome associated with threatening dysrhythmia which temporary pacemaker can be used for life-saving support.
Limeng Jiang +10 more
doaj +1 more source
Permanent His-bundle pacing: seeking physiological ventricular pacing [PDF]
Right ventricular apical pacing can have deleterious effects and the His bundle has been widely reported to be an alternative site. This paper presents our experience with permanent His-bundle pacing (HBP).Patients referred for pacemaker implants (regardless of block type) were screened to determine if temporary HBP corrected conduction dysfunctions ...
Rafael, Barba-Pichardo +4 more
openaire +2 more sources