Research on deformation mechanisms in deep excavation tunnels and the application of the pile foundation-unit-type support. [PDF]
Gou L +5 more
europepmc +1 more source
Transducers convert physical signals into electrical and optical representations, yet each mechanism is bounded by intrinsic trade‐offs across bandwidth, sensitivity, speed, and energy. This review maps transduction mechanisms across physical scale and frequency, showing how heterogeneous integration and multiphysics co‐design transform isolated ...
Aolei Xu +8 more
wiley +1 more source
A Review of Modelling Test Study on the Effect of Single-Line Tunnelling on Adjacent Piles: Test Materials, Methodologies and Results. [PDF]
Diao H, Lu Y, Hu H, Wei G, Li Q, Zhou X.
europepmc +1 more source
Tunable 3D‐Printed Static Mixers for Gradient Bioprinting With High Cell Viability
ABSTRACT The fabrication of native tissue‐like structures with gradual transitions in material properties, cell types, and growth factors remains a major challenge in biofabrication due to the lack of suitable methods. Mimicking the hierarchical organization of living tissues is essential for functional models, yet creating gradient, multimaterial ...
Florian Hofmann +9 more
wiley +1 more source
Calculation of ultimate bearing capacity and analysis of bearing characteristics for pile group foundation to underlying offset cave. [PDF]
Zhao Y +9 more
europepmc +1 more source
ABSTRACT Molybdenum disulfide (MoS2) has attracted attention as a promising material due to the growing demand for environmentally friendly, cost‐effective, and efficient water treatment techniques. With its physicochemical characteristics, this stratified bidimensional material allows it to be highly effective in adsorption and catalytic performance ...
Pariksha Bishnoi +4 more
wiley +1 more source
Design and evaluation of structural risk mitigation measures for transmission lines micro-pile foundations in mountainous region. [PDF]
Hu X, Xi X, Xiang Z.
europepmc +1 more source
Hierarchical multi‐material TPMS lattices are engineered as flexible tactile sensors by combining soft and stiff elastomeric layers with a conformal conductive coating. The bilayer architecture delivers sensitivity at low pressures while maintaining a broad detectable range under large loads, enabling reliable pressure and vibration monitoring for ...
Reza Noroozi +3 more
wiley +1 more source
Analysis of construction impact and safety evaluation of metro shield tunnel under-crossing existing bridge pile foundation. [PDF]
Xu J, Zhang X, Lin S, Feng D.
europepmc +1 more source
We introduce an additively manufactured bioreactor with a perfusion flow system and integrated temperature and pH sensors for skeletal muscle tissue biofabrication. The bioreactor's performance was evaluated by assessing the viability, spreading of the myoblast cells in a printed scaffold, and contraction of the isolated murine musculi interossei ...
Lys Sprenger +9 more
wiley +1 more source

