Design and performance of a compact and stationary microSPECT system [PDF]
Purpose: Over the last ten years, there has been an extensive growth in the development of microSPECT imagers. Most of the systems are based on the combination of conventional, relatively large gamma cameras with poor intrinsic spatial resolution and ...
Accorsi +34 more
core +2 more sources
Background A prototype anthropomorphic head and neck phantom has been designed to simulate the adult head and neck anatomy including some internal organs and tissues of interest, such as thyroid gland and sentinel lymph nodes (SLNs).
Mohammed S. Alqahtani +5 more
doaj +1 more source
Distribution and dynamics of Tc-99m-pertechnetate uptake in the thyroid and other organs assessed by single-photon emission computed tomography in living mice [PDF]
Background: Tc-99m pertechnetate is a well-known anion, used for clinical imaging of thyroid function. This gamma emitter is transported by the sodium iodide symporter but is not incorporated into thyroglobulin. Scintigraphy using Tc-99m pertechnetate or
Darcourt, Jacques +6 more
core +1 more source
Accurate molecular imaging of small animals taking into account animal models, handling, anaesthesia, quality control and imaging system performance [PDF]
Small-animal imaging has become an important technique for the development of new radiotracers, drugs and therapies. Many laboratories have now a combination of different small-animal imaging systems, which are being used by biologists, pharmacists ...
Bankstahl, Jens +5 more
core +1 more source
Simulated design strategies for SPECT collimators to reduce the eddy currents induced by MRI gradient fields [PDF]
Combining single photon emission computed tomography (SPECT) with magnetic resonance imaging (MRI) requires the insertion of highly conductive SPECT collimators inside the MRI scanner, resulting in an induced eddy current disturbing the combined system ...
Joseph, Wout +6 more
core +2 more sources
Background Multiple-pinhole (MPH) collimators improve the resolution–sensitivity trade-off compared to parallel-hole collimators. This study evaluated the impact of MPH collimators on intra- and between-rater agreement, and on the certainty of visual ...
Franziska Mathies +9 more
doaj +1 more source
The Optical Design of CHARIS: An Exoplanet IFS for the Subaru Telescope [PDF]
High-contrast imaging techniques now make possible both imaging and spectroscopy of planets around nearby stars. We present the optical design for the Coronagraphic High Angular Resolution Imaging Spectrograph (CHARIS), a lenslet-based, cryogenic ...
Brandt, Timothy +17 more
core +3 more sources
Gamma Radiation Imaging System via Variable and Time-Multiplexed Pinhole Arrays
Biomedical planar imaging using gamma radiation is a very important screening tool for medical diagnostics. Since lens imaging is not available in gamma imaging, the current methods use lead collimator or pinhole techniques to perform imaging.
Ariel Schwarz +6 more
doaj +1 more source
Non-destructive 3D imaging method using muonic X-rays and a CdTe double-sided strip detector
Elemental analysis based on muonic X-rays resulting from muon irradiation provides information about bulk material composition without causing damage, which is essential in the case of precious or otherwise unreachable samples, such as in archeology and ...
I-Huan Chiu +12 more
doaj +1 more source
Commissioning and performance results of the WFIRST/PISCES integral field spectrograph [PDF]
The Prototype Imaging Spectrograph for Coronagraphic Exoplanet Studies (PISCES) is a high contrast integral field spectrograph (IFS) whose design was driven by WFIRST coronagraph instrument requirements.
Cady, Eric J. +8 more