Results 181 to 190 of about 57,613 (230)
Some of the next articles are maybe not open access.

PIV error correction

Experiments in Fluids, 2000
A non-post-interrogation method of reducing subpixel errors and eliminating spurious vectors from particle image velocimetry (PIV) results is presented. Unlike methods that rely on the accuracy or similarity of neighboring vectors, errors are eliminated before correlation information is discarded using available spatial and/or temporal data.
openaire   +1 more source

Guidelines for the Authorization of PIV Card and Derived PIV Credential Issuers

2023
The document provides appropriate and useful guidelines for assessing the reliability of issuers of PIV Cards and derived PIV credentials. These issuers store personal information and issue credentials based on OMB policies and the standards published in response to HSPD-12. The reliability of an issuer is of utmost importance when an organization (e.g.
Hildegard Ferraiolo   +3 more
openaire   +1 more source

Acoustic PIV: Measurement of the acoustic particle velocity using synchronized PIV-technique

The Journal of the Acoustical Society of America, 2008
This paper outlines a technique for measuring the acoustic particle velocity and the flow field simultaneously by applying synchronized particle image velocimetry (PIV). As test set-up a squared acrylic glass chamber was chosen. One side of the test section is connected to a loudspeaker, which allows a sinusoidal excitation of the chamber. To point out
Fischer, A., Sauvage, E., Röhle, I.
openaire   +2 more sources

Analysis of stereoscopic PIV measurements using synthetic PIV images

2004
This paper describes the use of a synthetic image generator (SIG) for the assessment of the precision of a stereoscopic PIV system. The geometry implemented with the SIG closely matches that of an existing stereo-PIV measurement in laminar pipe flow. The calibration procedure is simulated, which demonstrates the necessity of a careful alignment between
Petracci, A.   +3 more
openaire   +3 more sources

Local field correction PIV: on the increase of accuracy of digital PIV systems

Experiments in Fluids, 1999
Cross-correlation Particle Image Velocimetry (PIV) has become a well known and widely used experimental technique. It has been already documented that difficulties arise resolving velocity structures smaller than the interrogation window. This is caused by signal averaging over this window.
J. Nogueira   +2 more
openaire   +1 more source

Piv-Propsi

Acta crystallographica. Section C, Crystal structure communications
The pseudodipeptide, (S)-N-isopropyl [N-(pivaloyl)pyrrolidin-2-yl]methylaminooxyacetamide, C(15)H(29)N(3)O(3), adopts a global extended conformation with the hydroxylamine group in the g(+)/g(-) structure. The C-terminal amide NH interacts intramolecularly with the hydroxylamine O atom.
, Corbier   +4 more
openaire   +1 more source

PIV - Anwendungen

open access: yes, 1999
Es wurden die Anwendungen der PIV Methode in der Aerodynamik ...
Kompenhans, J.
openaire   +2 more sources

Applications: Micro PIV

2018
This section discusses various applications and techniques used in \(\mu \text {PIV}\). The applications include very high spatial resolution measurements of pressure-driven flow in a rectangular capillary and measurements in a challenging toroidal vortex.
Markus Raffel   +5 more
openaire   +1 more source

PIV recording techniques

1998
In this chapter different approaches to PIV recording are introduced. It is important to realize that the various recording methods are not necessarily defined by the recording medium. The same approach may for instance be applied using either photography or digital recording. The PIV recording modes can be separated into two main branches: (1) methods
Markus Raffel   +2 more
openaire   +1 more source

Techniques for 3D-PIV

2018
This chapter initially provides the reader with an extensive survey of the many methods available to measure the flow velocity in three-dimensional problems. Afterwards, the chapter devotes three main sections to the most common or emerging methods: Tomographic PIV, 3D-PTV techniques and Shake-the-Box.
Markus Raffel   +5 more
openaire   +1 more source

Home - About - Disclaimer - Privacy