Results 171 to 180 of about 786,749 (367)
Abstract Purpose The dual‐layer multileaf collimator (MLC) in Halcyon adds complexities to the dose calculation process owing to the variability of dosimetric characteristics with leaf motion. Recently, an enhanced leaf model (ELM) was developed to refine the MLC model in the Eclipse treatment planning system. This study investigates the performance of
Ryohei Miyasaka+6 more
wiley +1 more source
Dual-Polarized Wideband Filtering Antenna Array Based on Stacked-PCB Structure
This paper investigates a thin low-pass filtering antenna array based on dual-polarized Vivaldi elements. The low-pass filtering in the antenna elements reduces the requirement for the front-end filtering between the antenna and the microwave electronics,
Matti Kuosmanen+5 more
doaj +1 more source
Abstract Purpose This study evaluates a novel cone‐beam computed tomography (CBCT) imaging solution integrated onto a conventional C‐arm linear accelerator (linac) with increased gantry speed. The purpose is to assess the impact of improved imaging hardware and reconstruction algorithms on image quality.
Theodore Arsenault+9 more
wiley +1 more source
Dipole and quadrupole planar magnetic fields produced by line currents [PDF]
Francine M. Deutsch
openalex +1 more source
Monte Carlo modeling of radiation dose from radiation therapy with superficial x‐rays
Abstract Introduction Superficial x‐rays (50–100 kVp) are used for treating non‐melanoma skin cancer and intraoperative radiation therapy (IORT). At these energies, the photoelectric effect significantly increases absorbed dose to bone compared to soft tissue.
Reham Barghash+3 more
wiley +1 more source
Maximal Planarization of Non - Planar Graphs
Abstract This paper presents a MAXIMAL - PLANARIZE algorithm using EQUIVELANT - GRAPH procedure . The algorithm proceeds by embedding one or few edges at each stage , without creating nonplanarity of the resultant graph , and to construct a maximal planar subgraph G , of G directly .
openaire +2 more sources
Abstract Purpose The aim of this study was to investigate the influence of the simultaneous multislice acceleration (SMS) technique as well as two‐dimensional (2D) and three‐dimensional (3D) tumor segmentations on radiomics features (RFs) within the parametric maps of cervical cancer, which were computed by intravoxel incoherent motion (IVIM) and ...
Shuangquan Ai+6 more
wiley +1 more source
Abstract Current radiotherapy practices rely on manual contouring of CT scans, which is time‐consuming, prone to variability, and requires highly trained experts. There is a need for more efficient and consistent contouring methods. This study evaluated the performance of the Varian Ethos AI auto‐contouring tool to assess its potential integration into
Robert N. Finnegan+6 more
wiley +1 more source
In vivo transit dosimetry methodology for whole breast intensity modulated radiation therapy
Abstract Background In vivo transit dosimetry using an electronic portal imaging device (EPID‐IVTD) is an important tool for verifying the accuracy of radiation therapy treatments. Despite its potential, the implementation of EPID‐IVTD in breast intensity modulated radiation therapy (IMRT) treatments has not yet been standardized, limiting its clinical
Lucia Zirone+8 more
wiley +1 more source