Results 51 to 60 of about 1,058 (177)

Optimizing Fabrication of Plasma‐Driven CuO Shell Over Porous Al2O3 Substrate to Meet Coating Issues

open access: yesJournal of the Chinese Chemical Society, EarlyView.
In situ Cu2O‐to‐CuO transformation during plasma electrolytic oxidation of aluminum alloys. ABSTRACT A plasma‐driven in situ conversion strategy was developed in which Cu2O nanoparticles introduced into an alkaline phosphate–hydroxide electrolyte undergo oxidative transformation to CuO within plasma micro‐discharge channels during plasma electrolytic ...
Sasithon Kaentown   +5 more
wiley   +1 more source

Atmospheric Corrosion Protection of LPBF Manufactured AlSi10Mg by Combining SiOx‐CVD and PDMS Grafting

open access: yesMaterials and Corrosion, EarlyView.
Hybrid SiOₓ‐CVD/PDMS ultrathin films mitigate atmospheric corrosion of additively manufactured AlSi10Mg. Electrochemical analyses show reduced corrosion currents, increased charge‐transfer resistance, and suppressed pitting due to diminished cathodic activity and limited oxygen and ion transport under NaCl exposure.
Tim Prüßner   +3 more
wiley   +1 more source

Plasma Electrolytic Oxidation (PEO) coatings on a zirconium alloy for improved wear and corrosion resistance [PDF]

open access: yesWIT Transactions on Engineering Sciences, 2010
Zr oxide coatings were deposited using plasma electrolytic oxidation (PEO) on Zr-2.5wt%Nb (Zr-2.5Nb) alloy, which is currently used for pressure tubes in the CANDU nuclear reactor. The effects of two PEO processing factors, electrolyte concentration and current density, on the microstructure and properties of the coatings were systematically ...
Y. Chen, X. Nie, D. O. Northwood
openaire   +1 more source

XPS and GDOES Characterization of Porous Coating Enriched with Copper and Calcium Obtained on Tantalum via Plasma Electrolytic Oxidation

open access: yesJournal of Spectroscopy, 2016
XPS and GDOES characterizations of porous coatings on tantalum after Plasma Electrolytic Oxidation (PEO) at 450 V for 3 minutes in electrolyte containing concentrated (85%) phosphoric acid with calcium nitrate and copper (II) nitrate are described. Based
Krzysztof Rokosz   +4 more
doaj   +1 more source

Electrospun conducting polymers: recent trends and the transition towards a sustainable future

open access: yesPolymer International, EarlyView.
This review discusses the electrospinning of conducting polymers, detailing procedures, fibrous morphologies, improved properties, applications in electronics, and challenges, while outlining future directions for nanofibre‐based devices in various fields.
Xenofon Karagiorgis   +3 more
wiley   +1 more source

Use of Organic Acids as Additives for Plasma Electrolytic Oxidation (PEO) of Titanium

open access: yesCoatings
The present study investigates the influence of organic acids, added to the electrolytic solution, on the structure, morphology, and corrosion behaviour of plasma electrolytic oxidation (PEO) coatings produced on titanium grade 2. Particular attention is paid to the role of functional groups in the modification of the oxide’s properties.
Federica Ceriani   +2 more
openaire   +1 more source

Erosion and corrosion resistance of plasma electrolytic oxidized 6082 aluminum alloy surface at low and high temperatures

open access: yesJournal of Materials Research and Technology, 2019
This paper embodies the findings of a study on improving the surface tribology of Al alloy 6082-T6 through plasma electrolytic oxidation (PEO) process. The surface macro/microstructure and composition were investigated.
Ali Algahtani, Essam R.I. Mahmoud
doaj   +1 more source

Cytocompatibility of porous P-containing coating prepared by plasma electrolytic oxidation of Mg alloy

open access: yesMaterials Research Express, 2020
Magnesium alloys are potential biodegradable hard-tissue implant materials because of their excellent biomechanical compatibility, biosafety, and absorbability.
Yang Jiao   +5 more
doaj   +1 more source

Engineered surface strategies to manage dental implant‐related infections

open access: yesPeriodontology 2000, EarlyView.
Abstract When exposed to the oral environment, dental implants, like natural surfaces, become substrates for microbial adhesion and accumulation, often leading to implant‐related infections—one of the main causes of implant failure. These failures impose significant costs on patients, clinicians, and healthcare systems.
João Gabriel S. Souza   +7 more
wiley   +1 more source

Bioresorbable Mo–W Electrodes: Toward an Extended Operational Lifetime Through Controlled Alloying and Oxide Coating Engineering

open access: yesAdvanced Materials Interfaces, Volume 13, Issue 11, 9 June 2026.
Bioresorbable electrochemical sensors face instability in biofluids. Although alloys can mitigate rapid in vivo dissolution, Mo–W remains underexplored for sensing. This work engineers Mo–W films with a nanocrystalline oxide coating, improving stability and enabling reliable oxygen and pH sensing for up to 10 days, highlighting their potential for ...
C. Fernandes   +4 more
wiley   +1 more source